D e v i c e d e s c r i p t i o n
The ASKOHEAT
is switched in 7 steps via the digital Modbus interface or the analogue 0‐10V input. In
‐F+
addi on, the maximum level up to 24 hours can be ac vated via the „Emergency On" bu on (Pos. 3) or
the digital input „Heat pump request".
The use of the interface is described in a separate document (Modbus protocl) and can be downloaded
from our homepage.
Te m p e r a t u r e c o n t r o l
The maximum temperature can be con nuously adjusted with the rotary knob (pos. 1). The range ex‐
tends from „Out" to approx. 85°C. For economic reasons, it should be set to approx. 65°C.
When the temperature is reached, the device switches off and on again automa cally if necessary.
S a f e t y t e m p e r a t u r l i m i t e r
If the safety temperature limiter has tripped, you can reset it with a "00 screwdriver" through the
opening marked "Reset". This cannot be done un l the temperature has cooled down by approx. 10K.
E m e r g e n c y o p e r a t i o n „ E m e r g e n c y O n "
The maximum hea ng output can be switched on immediately with the „Emergency On" bu on. To do
this, press the bu on for at least 2 seconds. This may be necessary in the event of a fault or if addi o‐
nal heat is required. To switch off, press the bu on again for at least 2 seconds. For safety reasons, the
ASKOHEAT
automa cally switches back to normal opera on a er 24 hours.
‐F+
A p p l i c a b l e
s t a n d a r d s
ASKOHEAT
‐F+
Flange heater Ø 180mm
for the user and qualified installer
Pos. 1
Pos. 2
Pos. 3
Pos. 4
Safety:
EN60335‐1 / ‐2‐21 / ‐2‐73
EMC:
EN55014‐1 / ‐2
CEM:
EN62233
IP Code:
EN60529
MVGASV_012‐6791_V01_en
Temperature control
Reset bu on
Emergency On
Opera ng lights
www.askoma.com