AMCI PressPro Genesis Handbuch Addendum - Seite 2

Blättern Sie online oder laden Sie pdf Handbuch Addendum für Controller AMCI PressPro Genesis herunter. AMCI PressPro Genesis 2 Seiten.

PressPro Genesis Manual Addendum
Solid State Outputs
There are two versions of the PressPro Genesis, one with Mechanical Relay Outputs, the GN3B1-
01A-00, and one with Solid State Relay Outputs, the GN3B1-01B-00. The standard user's
manual covers only the Mechanical Relay output.
The functions of the PressPro Genesis with Solid State relays are the same as those of a unit with
Mechanical relays.
The following diagram shows the location of the inputs and outputs on the GN3B1-01B-00 Solid
State version.
Note: The solid state relays used with the GN3B1-01B-00 are not included with the unit and
must be ordered separately. The two options are KD-6 (DC relays) or KA-3 (AC relays).
Solid State Relay Wiring
+
Each Relay output has two terminals. One is labeled
and the other that shows the Output
+
Number or Function. Connect your power supply to the
terminal and your load to the other
terminal.
+ 1 + 2
Output Number
+
Power
Load
Supply
COM
file: Genesis_press_pro_addendum
date: 1/25/06
20 Gear Drive, Plymouth Industrial Park, Terryville, CT 06786
page: 2
Tel: (860) 585-1254
Fax: (860)584-1973
Web:
www.AMCI.com