AME 15925 Gebrauchsanweisung - Seite 3

Blättern Sie online oder laden Sie pdf Gebrauchsanweisung für Industrielle Ausrüstung AME 15925 herunter. AME 15925 5 Seiten. 5qt. air pump w/ plastic reservoir

MAINTENANCE

1. Inspect hosed and connections daily.
2. Tighten connections as needed.
connections.
3. Use only good quality hydraulic fluid. We recommend Mobil DTE13M or equivalent.
When not in use or during storage:
a. Depressurize and disconnect hydraulic hoses from application.
b. Wipe clean, thoroughly.
c. Store in clean, dry environment. Avoid temperature extremes.
d. Shield pump with a protective cover.
Adding Hydraulic Fluid
1. Depressurize and disconnect hydraulic hose from application.
2. With pump in its upright, horizontal position, remove the oil filter plug located on the top plate of
reservoir.
3. Use a small funnel to fill reservoir to within ¾"(19mm) of the opening
Note: Use only good quality hydraulic jack oil
Never use brake fluid, transmission fluid, turbine oil, motor oil, alcohol, glycerin etc. Use of other than
good quality hydraulic oil will void warranty and damage the pump, hose and application.
4. Wipe up any spilled fluid and reinstall the oil filter plug.
Changing Hydraulic Fluid
1. For best results, change fluid once a year.
2. Repeat #2 above, then pour used fluid into a sealable container.
3. Dispose of fluid in accordance with local regulations
4. Fill with good quality hydraulic jack oil as recommended above. Reinstall vented oil filter pug.
Lubrication
Use a light machine oil to lubricate pivot points, hinges etc.
Note: Never operate pump with release valve closed and disconnected from application. If operated
in this condition, the hose and connections become pressurized. This increases burst hazard.
Damage may occur to pump and its components.
Use non-hardening pipe thread compound when servicing