Astralpool CTX Series Benutzerhandbuch - Seite 9

Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Schwimmbadpumpe Astralpool CTX Series herunter. Astralpool CTX Series 15 Seiten.
Auch für Astralpool CTX Series: Installations- und Betriebsanleitung (12 seiten)

Astralpool CTX Series Benutzerhandbuch

SECTION 5. TROUBLESHOOTING

FAILURE TO PUMP
Pump will not prime - too much air. Remedy:
1. Check suction piping and valve glands on any suction gate valves
2. Secure lid on pump strainer pot and make sure lid gasket is in place
3. Check water level to make sure skimmer is not drawing air
Pump will not prime - not enough water. Remedy:
1. Make sure suction lines, pump strainer, and pump volute are full of water
2. Make sure valve on suction line is working and open, (some systems do not have valves)
3. Check water level to make sure water is available through skimmer
Pump strainer clogged. Remedy:
1. Clean pump strainer pot
Pump strainer gasket defective. Remedy:
1. Replace gasket
REDUCED CAPACITY AND/OR HEAD
Air pockets or leaks in suction line. Remedy:
1. See item "Pump will not prime - too much air" of this section, above
Clogged impeller. Remedy:
1. Disassemble per SECTION III "Pump Disassembly"
2. Clean debris from impeller. If debris cannot be removed, complete the following steps:
a. Remove left hand thread anti-spin bolt and O-ring
b. Remove, clean and reinstall impeller
3. Reassemble per SECTION III "Pump Reassembly"
Pump strainer clogged. Remedy:
1. Clean suction trap
9