Akw M17 DigiPump Installations- und Pflegeanleitung - Seite 16
Blättern Sie online oder laden Sie pdf Installations- und Pflegeanleitung für Sanitärprodukt Akw M17 DigiPump herunter. Akw M17 DigiPump 20 Seiten. Digipump
Problem Solving
Problem Solving
PUMP WILL START BUT DOES NOT PUMP WATER
Check Non-Return Valves are
correctly fitted and oriented in the
inlet and outlet pipe connectors.
Ensure all push-fit pipe connections are fully sealed and O-rings are not
The water pumping capacity can be adjusted by adjusting pump speed.
Adjust pump speed using the calibration setting. Please refer to pump set up.
When increasing the pump speed, if the pump still performs low or no
suction, take off the pump head by removing the clamp ring. Examine
the inlet and outlet flap valves for traces of hard debris such as grit.
If so, wash out all debris and ensure the non-return valves are seated correctly.
If problem persists, check all connections for air leaks or blockage in either
The pump has an overrun timer to allow it to continue to run after the
shower has been switched off. This timer is factory set to 20 seconds.
With the power supply switched on, disconnect the flow sensor. Separate
the disconnected wires. This will simulate the flow sensor turning off.
Pump should stop after the overrun time. If not, check the controller
display panel or cabling. If the pump has not stopped, disconnect power
Is the controller working, remove and check the flow sensor, flush it
damaged or displaced.
the inlet or outlet pipework. Repair any leaks and clean blockages.
PUMP WILL NOT STOP
supply and contact customer services.
through with water or replace it as necessary.
Confirm
plastic
are NOT used. (see page 9
installation)
16
pipe
inserts