Air King 9230 Betriebsanleitung und Teilehandbuch

Blättern Sie online oder laden Sie pdf Betriebsanleitung und Teilehandbuch für Fan Air King 9230 herunter. Air King 9230 4 Seiten. 30" floor fan
Auch für Air King 9230: Betriebsanleitung & Teilehandbuch (3 seiten)

Air King 9230 Betriebsanleitung und Teilehandbuch
22
6
4
3
5
2
1
Rev. I 9/06
MODELO 9230
9
8
13
10
14
7
11
12
12
11
20
22
19
18
17
Ref
No. De
Descripción
No.
Parte
1
02084613
Adorno Tipo Ojo de Buey
2
5097140BK
Rejilla Delantera
3
5081021BK
Paleta
4
5090012
Tornillo 5/16-24
5
5090012
Tornillos del motor 10-32 X 5/16
Rejilla Trasera con Placa
6
5097010BK
de Pivote Con Hexagonal
7
*
Bolt 1/4-20 X 1"
8
5062211BK
Manija
9
05010051
Empuñadura de la manija
10
5062085BK
Pedestal
11
*
Arandela de Seguridad
12
*
Perno de 1/4-20 X 3/4"
13
02030024SK
Perilla del Interruptor
14
02030024SW
Interruptor
15
02030224
Conjunto del Motor
16
02030024CS
Juego de Alambre Flexible
17
5090050
Eje tapa Perno
18
05010050
Ruedas
19
5062215BK
La Barra del Eje
20
5062215BK
Escuadra de montaje
21
2090058B
Tornillo #8 X 7/16
22
02011601
Espaciador de caucho
* Articulo Incluyendo el numero de Empaques 5098012
** Patas de caucho con remache no incluidas
8
15
16
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.
PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
7
17
18
21
DESCRIPTION
The AirKing 30" (76.2 cm) pivot/floor fan features 3-speed operation
with a 3-paddle fan blade. The fan has an enclosed motor with
permanently lubricated ball bearings with a 10 ft (3.05 m) 18/3 cord set,
and is constructed of sturdy powder coated steel.
SPECIFICATIONS
Motor ................................. 120V , 50/60 Hz
Blade diameter .................. 30" (76.2cm) Model 9230
Speeds .............................. 3
Control .............................. Rotary Switch
Air flow distribution ........... 190˚
Approvals .......................... UL Listed. Close mesh fan guard
Cant.
1
MODEL
1
SPEED
1
CFM
1
M
3
/s
5
RPM
1
Amps
4
Watts
1
dB A
1
2
2
UNPACKING
2
When unpacking the unit, inspect carefully for any damage that
1
may have occurred during transit. Check for loose, missing, or
1
damaged parts.
1
1
GENERAL SAFETY INFORMATION
2
1. Read all instructions before using Fan.
2
2. Make certain that the power source conforms to the electrical
1
requirements of the Fan.
1
3. Use this Fan only as described in this manual. Any other use not
2
recommended by the manufacturer may cause fire, electrical
2
shock, or injury to persons.
4. To reduce the risk of personal injury and electric shock, the Fan should
not be played with or placed where small children can reach it.
5084029
Rev. I 9/06
OPERATING INSTRUCTIONS & PARTS MANUAL
30" FLOOR FAN
30" (76.2 cm) MODEL 9230
READ AND SAVE THESE INSTRUCTIONS
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
5. Unplug power cord before installing, servicing, or moving the Fan.
WARNING:
THE SOLE MEANS OF DISCONNECTING POWER WHEN IN-
STALLING OR SERVICING THE FAN. ALWAYS UNPLUG THE
POWER CORD.
6. This Fan must NOT be used in potentially dangerous
locations such as flammable, explosive, chemical-laden
or wet atmospheres.
7. DO NOT use Fan in or near a window. Rain may create an
electrical hazard.
8. Completely assemble Fan, according to instructions, before
connecting to power supply.
9. The power cord is equipped with a three-prong grounded plug
that must be inserted into a matching receptacle. Under no cir-
cumstances should the ground prong be cut off the plug. Where
a two-prong wall receptacle is encountered, it must be replaced
with a properly grounded three-prong receptacle installed in ac-
cordance with the National Electrical Code (NEC) and all appli-
cable local codes and ordinances. This work must be done by a
qualified electrician, using copper wires only.
WARNING:
PROPER CONNECTION MAY CAUSE THIS RISK OF ELEC-
TROCUTION. USE OF SUCH ADAPTERS IS NOT PERMITTED
IN CANADA.
10. Where possible, avoid the use of extension cords. If they must be
meets OSHA requirements.
used, minimize the risk of overheating by ensuring that they are
UL listed. Never use a single extension cord to operate more than
9230
one Fan.
HIGH
MED
LOW
11.Do not operate any Fan with a damaged cord or plug or after the
7400
6360
4980
Fan malfunctions, has been dropped or damaged in any manner.
Return Fan to authorized service facility for examination, electrical
3.49
3.00
2.35
or mechanical adjustment or repair.
1110
975
822
12.Do not insert or allow fingers or foreign objects to enter any
2.04
1.81
1.60
ventilation or exhaust opening as it may cause an electric shock
234
206
176
or fire, or damage the Fan. Do not block or tamper with the Fan
75
71
67
in any manner while it is in operation.
13.Always place the Fan on a stable, flat, level surface when
operating, to avoid the chance of the Fan overturning. Locate the
Power Cord so the Fan or other objects are not resting on it. Do
not run Power Cord under carpeting. Do not cover Power Cord
with throw rugs, runners, or the like. Arrange Power Cord away
from room traffic and where it will not be tripped over.
14.This Fan is not intended for use in wet or damp locations.
Never locate a Fan where it may fall into a bathtub or other
water container.
15. Do not use Fan outdoors.
WARNING:
SHOCK – DO NOT USE THIS FAN WITH ANY SOLID STATE
SPEED CONTROL DEVICES.
1
DO NOT DEPEND UPON THE ON-OFF SWITCH AS
DO NOT USE A THREE-PRONG ADAPTER. IM-
REDUCE THE RISK OF FIRE OR ELECTRIC
SAVE THESE
INSTRUCTIONS
5084029