Baumer Hubner Berlin PMG 10-SSI Installations- und Betriebsanleitung - Seite 15

Blättern Sie online oder laden Sie pdf Installations- und Betriebsanleitung für Medienkonverter Baumer Hubner Berlin PMG 10-SSI herunter. Baumer Hubner Berlin PMG 10-SSI 28 Seiten. Absolute encoder with magnetic sensing

5.2
Data transfer SSI
Clock
Data
Clock frequency
Period (T)
Time lag (t1)
Monolop time (t2)
n, m
i
For continous clocking, the SSI word is transmitted only once followed by zero valu-
es (no ring register operation)�
5.3
Output signals incremental (additional outputs)
At positive rotating direction
A+
A-
B+
B-
R+
*
Zero pulse+
*
R-
Zero pulse-
* Only additional output 2
MB245EN - 11171693, 16A1, Baumer_PMG10-SSI_II_EN
Position
Speed
n-1...0 bit m-1...0 bit
msb → lsb msb → lsb
100 kHz���2 MHz
0�5...10 µs
0�25...5 µs
20 µs (internal)
Number of bits
ELECTRICAL CONNECTION / DATA TRANSFER SSI
t2
90°
12/25