• READ THESE INSTRUCTIONS FULLY BEFORE INSTALLING
THIS PRODUCT.
• SAVE THESE INSTRUCTIONS FOR REFERENCE.
• WHEN DRILLING OR CUTTING INTO DUCTING BE
EXTREMELY
CAREFUL
CONDITIONING COILS OR OTHER FURNACE APPARATUS.
• THIS UNIT MUST BE INSTALLED IN 10" WIDE DUCT
MINIMUM.
• FOR THIS UNIT TO OPERATE PROPERLY YOUR FURNACE
SHOULD ACHIEVE A HEATING TEMPERATURE OF AT LEAST
35'C (95'F) IN ONE MINUTE. IF IT DOES NOT YOU MAY
HAVE TO PURCHASE A SECONDARY ACTIVATION SWITCH
(SOLD SEPARATELY).
• DO NOT INSTALL THIS UNIT WHERE EXTREME
TEMPERATURES EXIST (BELOW 8'C / 45'F OR ABOVE 63'C /
145'F).
• THIS UNIT REQUIRES A DRAIN TO ALLOW WATER TO
FREELY RUN OFF.
• FOR THIS UNIT TO OPERATE PROPERLY IT MUST BE
INSTALLED ON A FORCED AIR HEATING SYSTEM WITH A
SUPPLY DUCT AND RETURN DUCT.
• THE HUMIDIFIER BODY AND THE BYPASS COLLAR DAMPER
ARE TO BE INSTALLED ON DUCTING ONLY. UNDER NO
CIRCUMSTANCES MOUNT ANY COMPONENT TO THE
FURNACE BODY.
• ELECTRICAL WIRING, WATER SUPPLY, AND DRAIN TUBE
MUST NOT KINK OR COME INTO CONTACT WITH SHARP
EDGES OR HOT SURFACES.
• IF REPLACING AN EXISTING FURNACE HUMIDIFIER, WE
RECOMMEND YOU REPLACE ALL COMPONENTS TO
ENSURE PROPER HUMIDIFIER OPERATION.
• THE INSTALLATION OF THIS PRODUCT MUST COMPLY
WITH NATIONAL AND LOCAL ELECTRICAL, PLUMBING,
BUILDING, AND MECHANICAL CODES.
REQUIRED TOOLS
• Safety glasses
• Work gloves
• Electric or cordless drill
• Drill bits (3/8", 1/8", 7/32", 7/64")
• Tin snips
• Full size Philips or Roberstons screw driver
• Short handle Philips or Roberstons screw driver
• Adjustable wrench
• Utility knife
• Pliers
• Level
• Measuring tape or ruler
• Medium-grit sand paper
• Pencil
Call 1-800-667-8721 anywhere in the US and Canada
Model 7000 Flow Through Humidifier
INSTALLATION AND OPERATING INSTRUCTIONS:
MODEL 7000 FLOW THROUGH HUMIDIFIER
NOT
TO
DAMAGE
SELECTION OF LOCATION
TO MOUNT THE HUMIDIFIER
All bypass type furnace mount humidifiers rely on the pressure
difference which exists between the supply duct (hot air) and the
AIR-
return duct (cold air) to create an air flow through the
humidifier's evaporator pad. The air will ALWAYS flow from Hot
(high pressure) to Cold (low pressure).
Selecting the proper location and installing the humidifier
properly as intended by the manufacturer is imperative for the
proper operation of the humidifier. See illustrations below along
with the brief explanations as to what a good installation is and
what is not.
•INSTALLATION TIP: Before starting fully plan out the
installation. Check for the locations of the humidifier,
bypass collar & damper, and the humidistat and
associated sensors. Plan the length and type of ducting
required, the water supply, the water drain, the electrical
wiring, and a constant 120 volt outlet to plug in the
transformer. This will ensure your installation goes as
easy and quickly as possible
IDEAL INSTALLATION
Figure 1
SUPPLY DUCT
Damper fully open
1. The humidifier body and bypass tube are installed at eye level,
easily accessible for installation and routine maintenance.
2. The space between the humidifier body and bypass tube are no
more than 30" to ensure maximum air flow through the humidifier.
3. The supplied aluminum flex bypass tube are cut to the proper
length and pulled tight to ensure maximum air flow.
4. The bypass damper is fully open.
5. The humidifier is mounted level on the duct.
6. There is nothing inside the duct behind the bypass collar &
damper or the humidifier body.
7. The humidifier and bypass collar and damper are level.
::
kitchensource.com
RETURN DUCT
COLD AIR
WARM AIR
No more
than 30"
3
10" wide duct minimum
Bypass collar and
unit level
Bypass tube pulled
tight and cut to length
Water flowing to drain