8
selecting a location to mount the humidistat keep in mind the
following.
• The humidistat should be at least 6" above the humidifier body.
To ensure humidified air being introduced into the duct is not
being sensed.
• The humidistat should always be mounted on the return duct
(cold air). This will ensure that the air from the living area is being
sensed.
• Try to avoid areas where fresh air is being introduced into the
return duct. This will cause false readings. It will always be better
to locate the humidistat up stream from any Fresh Air intake.
• The humidistat comes with 3 feet of cable for connection to the
humidifier. If your installation requires a longer cable, a 10 foot
length of cable can be purchased through our Parts & Service Line,
Part Number 011175001.
The humidistat comes packaged from the factory fully assembly
along with the cable for power connection to the humidifier, the
outdoor air sensor (for use in automatic mode only), and 2
humidistat labels, one if the humidistat is in manual mode and
other for automatic mode. To install the humidistat you will first
have to disassemble it.
humidistat knob, to remove the front cover use a slot screw driver
and insert the end into the opening in the humidistat housing as
shown. This will expose the Control Base and board. You may
now mount the control in the selected location.
Figure 20
1. Affix the humidistat mounting template to the duct using tape.
(Combination template with the humidifier body template.)
2. Drill the 4 marked mounting holes
3. Drill a 3/8" hole inside the rectangle marked Humidistat Cut
Out.
4. Using the 3/8" hole as a starting point cut out the Humidistat Cut
Out using tin snips (not supplied.
5. Mount the humidistat control to the duct using the 4 screws
packaged with the humidistat.
6. Connect the control cable to the humidistat (fig 21.)
7. Connect the other end of the control cable to the humidifier side
panel. (fig 22)
HUMIDISTAT CONTROL–SETTING AUTOMATIC OR MANUAL OPERATION.
You have an option of selecting one of two operation modes for
your humidistat. There is a switch on the side of the humidistat
for setting Automatic or Manual – With the Switch in the UP
position the humidistat is in Manual, if the switch is in the
Referring to figure 20, remove the
Figure 21
DOWN position the control is in
Automatic. Also provided are two humidistat labels, one for
Automatic (Fig 23) and one for Manual (Fig 24)
Manual Humidistat Operation. (Switch UP) – With the control
set up for manual operation it will work the same as a normal
Figure 23
Figure 24
the humidistat front cover, position the manual humidistat label,
and replace the knob.
Automatic Humidistat Operation. (Switch DOWN) – With the
control set up for automatic operation the control will
automatically adjust the humidity set point based on outdoor air
temperatures. The purpose of this feature is to protect against
over humidification and condensation problems. Referring to the
chart below (fig 25) the control will achieve no higher humidity
levels than that shown for corresponding outdoor air temperature
and dial setting. An example is shown, with the control set at 5
and an outdoor air temperature of 0'C/30'F the maximum
humidity level achieved will be 40%. The humidity levels used
in automatic mode are based on ASHRAE standards to protect
against over humidification.
humidistat in automatic mode you will have to install the outdoor
Figure 25
outside window where a representative outdoor air temperature
Figure 22
humidistat.
DO NOT use or
connect
outdoor air sensor
and you will have
to set the desire
Automatic Mode
humidity level and
make all necessary
a d j u s t m e n t s
manually.
select to operate
the humidistat in
manual operation
no further set up is
Manual Mode
required. Replace
If you select to operate the
air temperature sensor.
The sensor plugs into the
control board next to the
main cable (fig 26). The
other end of the sensor
wire ideally should be
placed outside and held in
place
via
a
(supplied)
holding
sensor head (fig 27). If you
are unable to get the
sensor
outside
acceptable to place the
sensor on the surface of an
You
the
If you
screw
the
it
is