Andersen Verilock 0106512 Benutzerhandbuch - Seite 8

Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Sicherheitssensoren Andersen Verilock 0106512 herunter. Andersen Verilock 0106512 16 Seiten. For a-series and 400 series windows and patio doors, 200 series patio doors and renewal by andersen windows

Battery Replacement Instructions - continued
400 Series and Renewal by Andersen DB
Double-Hung Windows
1. Rotate the lock handle 90 degrees from the locked
position and remove both screws.
2. Rotate lock handle counterclockwise an additional 90
degrees to the full unlocked position.
3. Remove lock from sash.
4. Locate the battery compartment on the bottom of
the VeriLock lock.
5. Carefully remove battery cap.
6. Remove discharged battery from the VeriLock lock
using a small flat blade screwdriver to carefully pry
the battery from the terminal. (see battery disposal
information on page 5).
7. Replace the battery with a fresh CR-2025 lithium
coin cell battery into the battery ring, with the
positive (+) side facing out.
8. Reapply battery cap.
9. Reinstall VeriLock lock on the lower sash.
10. Move the upper and lower sash into the closed
position and lock the unit.
11. Verify that the sensor is communicating with your
security system or self-monitoring application by
unlocking the window and checking for the unlocked
message and then opening the window and checking
for the window open message.

Renewal by Andersen DG Double-Hung Windows

1. Remove battery cover by pressing front right side of
cover and sliding cover away from lock.
2. Carefully lift up battery cap to reveal battery.
3. Remove discharged battery from the VeriLock lock
using a small flat blade screwdriver to carefully pry
the battery from the terminal. (see battery disposal
information on page 5).
4. Replace the battery with a fresh CR-2025 lithium
coin cell battery into the battery ring, with the
positive (+) side facing up.
5. Reapply battery cap.
6. Reinstall battery cover by pressing front right side of
cover and sliding under lock. Assure cover is flush
and fully seated.
7. Verify that the sensor is communicating with your
security system or self-monitoring application by
unlocking the window and checking for the unlocked
message and then opening the window and checking
for the window open message.
9142268
400 Series and Renewal by Andersen DB
Double-Hung Windows
Small
Flat Blade
Screwdriver
Insert screwdriver
into slot end to
remove battery.
Renewal by Andersen DG
Double-Hung Windows
VeriLock
Cover
Battery
Cap
Small Flat Blade
Screwdriver
Insert screwdriver
into slot end to
remove battery.
8
User's Guide
VeriLock Lock
Battery Cap
CR-2025
Battery
Press front right side
of cover and slide from
under lock.
CR-2025
Battery