Step6
Electrical
TheBoschdryercomes with4-wire power s upply
cordpre-installed. Thiscordfitsa 4-wire receptacle
as shown intheupper section ofFigure 1.
If your receptacle is a 3-wire receptacle, as shown in
the lower section of Figure 1, a 3-wire "Dryer Cord"
must be purchased locally. The 4-wire cord must then
be removed and the 3-wire cord installed in its place,
Electrical Connection, 4-Wire
For a 4-wire system, all that is necessary is to plug
the 4-wire power supply cord into the 4-wire
receptacle of the proper rating.
Note: The receptacle should be located so that the
plug and receptacle will be accessible when
the dryer is in its final installed position.
Electrical Connection,
3oWire
If your receptacle is a 3-wire receptacle as shown
below, Figure 9, you must obtain a 3-wire dryer cord.
Dryer cord can usually be found at your local
hardware supply, electrical supply or home center.
Cord should have closed loop or upturned end wire
terminating connectors.
3- wire receptacle
__.
(10-30R) _'_
Typical 3-wire Dryer Cord
240V/30 amp NEMA 10-30 Type SRDT
Figure 9.
Note: If the dryer is installed in a mobile home or in
areas where local codes do not permit
grounding, only a 4-wire power supply cord
shall be used.
To Change Cord:
1.
Make sure that the dryer is not plugged into any
power outlet.
DO NOT plug end of dryer power cord into
a live receptacle
before connecting
dryer
power cord to dryer terminals
and closing
junction/splitter
box as described
below.
DO NOT reuse old power supply cord.
Power cord must be changed only be a
qualified person.
2.
Remove the screw from the cover of the
junction/splitter
box located at the top rear of the
dryer
3.
Remove the green ground wire from the ground
terminal.
4.
Remove the red, white and black wire from the
terminal block.
5.
Loosen the 2 screws in the U.L. strain relief
clamp, holding the 4-wire cable.
6.
Thread the 4-wire cable out through the U.L.
strain relief clamp and throw away.
7.
Thread the new 3-wire dryer cord through the
U.L. strain relief clamp.
8.
Attach the power cord Ground conductor (the
center wire) to the Ground terminal. Tighten the
terminal so that it securely holds the Ground
conductor.
9.
Attach the two remaining power cord outer
conductors to the 2 terminals labeled L. Tighten
both screws so that the power conductors are
securely held in place. See
Figure 10.
10. Tighten the screws on the U.L. strain relief so
that the power cord cannot be moved.