IN ORDER TO PERFORM THIS TASK, WEAR PERSONAL PROTECTION EQUIPMENT; GLOVES,
LONG SLEEVE SHIRT WITH NO GAPS BETWEEN CUFFS AND GLOVES, AND AN ULTRAVIOLET
BLOCKING FACE SHIELD MUST BE WORN TO COVER AND PROTECT EYES AND EXPOSED SKIN.
1.
When the treatment time has been determined, set the Sanidyne
of the room to be treated. (Treatment is most effective when the sanitizer is in the center of the room and the ultraviolet
rays are unobstructed.)
2. Post the warning sign(s) outside the entrance(s) to the area being treated and notify the appropriate persons that the area
should not be entered until the disinfection cycle is complete.
3. Connect power to the Sanidyne
the red power indicator and toggle switch will illuminate.
4. Remove the protective storage cover.
5. Set the required time using the HOURS and MINUTES up and down buttons. When the Treatment time is displayed
correctly, the START button can be pushed. An audio alarm will start beeping.
6. Pressing the START button again will pause the timer and allow a change of the time settings if required. Push again to reset
and restart the exit time.
7. Leave area quickly (within 1 minute, 30 seconds) to avoid ultraviolet exposure.
8. After the 1-minute, 30-second exit period, the beeper will stop and the treatment time will commence.
MAINTENANCE
Always disconnect power to the fixture before performing any service or maintenance.
IN ORDER TO PERFORM THIS TASK, WEAR PERSONAL PROTECTION EQUIPMENT; GLOVES,
LONG SLEEVE SHIRT WITH NO GAPS BETWEEN CUFFS AND GLOVES, AND AN ULTRAVIOLET
BLOCKING FACE SHIELD MUST BE WORN TO COVER AND PROTECT EYES AND EXPOSED SKIN.
•
The Sanidyne
Prime is designed to operate with a minimal amount of maintenance.
®
•
A regular cycle of cleaning the STER-L-RAY
experience. The frequency of cleaning will vary with the conditions surrounding each installation. It is recommended that the
germicidal lamp(s) and Sanidyne
•
The STER-L-RAY
Germicidal Ultraviolet Lamps used in the Sanidyne
®
average effective life of 13,000 hours. STER-L-RAY
reduction in ultraviolet output will make it impractical to use past the manufacturer's rated life. For maximum efficiency lamp
replacement is recommended every 13,000 hours of operation.
•
Unless lamp replacement is due to failure or breakage, it is recommended that all lamps be replaced at the same time.
•
It is recommended that the user maintain a log of all maintenance performed on Sanidyne
l
i
, r
amP
nstallation
NOTE: STER-L-RAY
lamps used in the Sanidyne
®
covering over the glass of the lamp — DO NOT REMOVE this covering.)
Always disconnect power to the fixture before performing any service or maintenance.
Germicidal lamps are easily damaged and may cause injury if broken. Exercise care when handling.
1. To remove lamps, follow the steps in "Lamp Installation" on Page 8 in reverse order.
2.
Moisten a clean, lint-free cloth with denatured alcohol and wipe down the outer surface of the lamp.
3.
When lamp has been removed and cleaned, then safely set aside, remove any loose dust or dirt from the surface of the fixture
with a soft, dry cloth or vacuum.
To reinstall lamps, follow the steps in "Lamp Installation" on Page 8.
4.
Prime and turn the power on using the toggle switch on the rear of the fixture. Once done,
®
If it is necessary to re-enter the treatment area before the end of the treatment cycle,
protective clothing, gloves and ultraviolet blocking face shield MUST be worn!
Germicidal Lamps MUST be established based on visual inspection and
®
Prime surfaces be cleaned at least once every three (3) months.
®
,
C
ePlaCement
or
leaning
Prime have ArmorLite
®
Prime on a cleared table or on the floor in the center
®
Prime fixture have a manufacturer's rated
®
lamps may operate longer than their rated effective life, but the
®
Safety Shield (which is a protective
TM
Prime. (See page 15)
®
(Continued on Page 12)
11