Bose PowerShare PS604A Installations- und Betriebshandbuch - Seite 19
Blättern Sie online oder laden Sie pdf Installations- und Betriebshandbuch für Verstärken Bose PowerShare PS604A herunter. Bose PowerShare PS604A 40 Seiten. Adaptable power amplifiers
pro.Bose.com
PS602 Rear Panel
Figure 3. PowerShare PS602 amplifier rear panel
q
q INPUT 1 & 2 – Balanced 3-pin Euroblock and unbalanced RCA line-level input connectors. For each channel, use either
balanced or unbalanced input type, but not both simultaneously.
w USB – Connect the amplifier to a PC using a USB connection. This allows you to use the PC-based PowerShare Editor
software to configure the advanced features of the amplifier. The CONFIG DIP switch must be set to SOFTWARE to
configure the amplifer using the PowerShare Editor software. See the Software Interface section for more details.
e CHANNEL 1 & 2 EQ – Each dial provides loudspeaker equalization presets per channel: DS 16, DS 40, DS 100, FS3B,
402, 802, MA12EX, RMU105, and RMU108. Use the Flat setting for FS3 Systems, or for loudspeakers that are not Bose
or that do not require EQ. When EQ is selected, the crossover and Vpeak and Vrms limiters for that loudspeaker are
automatically loaded. Use the PowerShare Editor software to adjust any of these parameters - see the Software Interface
section for more details. In Hi-Z output mode, a 50 Hz high-pass filter (HPF) is automatically added to the Hi-Z selected
outputs. The loudspeaker EQ is applied after the 50 Hz HPF.
r CONTROLCENTER – RJ-45 input connector for Bose® CC-1 ControlCenter zone controllers or CV41 4-to-1 Converter only.
Do not use this input to connect to a network.
t MUTE – Contact closure connection where a short across the mute connector will mute all outputs. This is the Normally
Open (NO) default state. The mute polarity can be inverted to Normally Closed (NC), where an open across the mute
connector will mute all outputs, using the PowerShare Editor software. See the Software Interface section for more
details.
y DIP Switches – A bank of switches used to set the amplifier configuration. All switches set to the left position is the
standard configuration.
• AUTO STANDBY – If enabled (ON), the amplifier goes into lower-power mode after twenty minutes without an input
signal. If in lower-power mode and an audio signal is detected, the amplifier will automatically wake and amplify
audio within 1 second. The default position is OFF.
• GLOBAL OUT – Sets the output capability to 70V or 100V for all outputs that have their OUTPUT DIP switch set
to Hi Z. In 70V mode, a 100V limiter is automatically loaded. In 100V mode, a 141 Vpeak limiter is automatically
loaded. These are maximum values that can be lowered using the PowerShare Editor software if necessary. See the
Software Interface section for more details.
• CONFIG – In REAR mode, the rear panel EQ settings are all that are required to configure the amplifier. In
SOFTWARE mode, the PowerShare Editor Software configures the amplifier, and the rear panel EQ switches are
ignored. The rest of the DIP switch settings are always independent of the PowerShare Editor Software settings, as
the software does not interface with any other DIP switches. See the Software Interface section for more details.
• SENSITIVITY – Select 4 dBu or 12 dBu as the amplifier sensitivity for the Euroblock line-level inputs. The unbalanced
RCA input sensitivity is -10 dBV in the 4 dBu sensitivity setting, and -2 dBV in the 12 dBu sensitivity setting.
• OUTPUT 1 – Select 70/100V high impedance output (Hi Z) or 4-8 Ω low impedance output (Low Z) for OUTPUT 1.
• OUTPUT 2 – Select 70/100V high impedance output (Hi Z) or 4-8 Ω low impedance output (Low Z) for OUTPUT 2.
u OUTPUT ATTEN 1 & 2 – Output attenuators for each output. Turn the attenuators clockwise to decrease attenuation,
and counter-clockwise to increase attenuation. Fully clockwise is 0 dB attenuation; fully counter-clockwise is mute. If
CC-1 zone controller(s) are used, then the CC-1 becomes the master volume control(s). The position of each attenuator
will determine the CC-1 zone controller range for that output. Set each trim to 0 dB attenuation to allow each CC-1
zone controller to have full attenuation range. If the CC-1 is disconnected from the amplifier, then the output attenuator
becomes the active setting.
i OUTPUT – Two inverted 2-pin Euroblock connectors for loudspeaker connections. Each channel can deliver up to 600
watts regardless of load into 4 Ω, 8 Ω, 70V, or 100V. Outputs are not bridgeable.
o AC Inlet – Removing the AC cord when the amplifier is on is equivalent to powering down using the front panel power
switch, and is an acceptable power-down method.
Installation Guide
w
e
r
1. FLAT
4
5
6
2. DS16
3
7
3. DS40
2
8
1
9
0
4. DS100
5. FS3B
6. 402
7. 802
5
4
6
8. MA12EX
3
7
2
8
9. RMU105
1
9
0
0. RMU108
t
y
MUTE
OFF
ON
AUTO STANDBY
70V
100V
GLOBAL OUT
REAR
SOFTWARE
CONFIG
4 dBu
12 dBu
SENSITIVITY
Hi Z
Low Z
OUTPUT 1
Hi Z
Low Z
OUTPUT 2
Front and Rear Panels
u
i
o
OUTPUT
ATTEN
-∞
0
-∞
0
100-240V ~ 50/60Hz 700W MAX
PowerShare
PS602
English 19