After final programming a time sale can be effected with the EMS-8x. The following description
refers to factory default programming of the EMS-8x.
The EMS-8x has a 3-digit LED-Display, that shows the customer the current state of the device. A
survey you can find in the following figure.
Special display messages for EMS-8x-TE:
Overview display messages
Before starting the payment, the device must be free, i.e. the display must show "0". After insertion
of the first coin, the EMS-8x indicates the released time. As far as the minimum insertion is not
achieved, the time is indicated flashing. When the min. insertion is achieved by inserting a further
coin, the display does not flash any more and the device starts. If further coins are inserted, the
currently released time is indicated. If the maximum time is achieved, the coin selector will be
blocked and additional coins can not be inserted anymore.
While the time runs down, the decimal point will blink and the displayed time will decrease by one
every minute that expires. During the last minute the display changes and the remaining seconds
are displayed. After the time has run out completely the display shows „0" and the output shuts
off.
This feature is mainly provided for washing machines and dryers. As some washing machines or
dryers need power in order to open the door, the EMS-8x-TE owns a push button at the front, that
can be used for switching the output for a moment. The duration can be determined by parameter
P36 within the programming area. During this time the door of the device may be opened. This
procedure may be repeated as often as programmed at parameter P35. If the key was pressed too
often, the door opener will be blocked for a certain time. This time can be programmed with
parameter P37. After the blocking time has run out the output can be switched again as described
before.
The connected device is free. Coins can be inserted.
Coins have been inserted an the minimum insertion has not be achieved
yet. Further coins must be inserted.
Coins have been inserted. The device is running.
Further coins can be inserted.
The output is released for 0.5 minutes in order to open the door of the
washing machine or the dryer.
The door is looked for the time which is setup in P37.