DSC Power 832 Benutzerhandbuch - Seite 11

Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Kontrolleinheit DSC Power 832 herunter. DSC Power 832 20 Seiten. Central station talk / listen module
Auch für DSC Power 832: Gebrauchsanweisung (11 seiten), Gebrauchsanweisung (18 seiten), Gebrauchsanweisung (2 seiten), Installationsanleitung Handbuch (12 seiten), Einbauanleitung (2 seiten), Einbauanleitung (2 seiten), Installationshandbuch (17 seiten)

DSC Power 832 Benutzerhandbuch

Viewing Trouble Conditions

The control p anel continuously monitors a numb er of possible trouble conditions. If one of these trouble
conditions oc cur, the keyp a d will b e e p twic e every 10 se conds until you press any key on the keyp a d.
Troubles c an only b e viewe d when the system is in the disarme d state. If a trouble oc curs while the
system is arme d, enter your a c c ess cod e to disarm the system, then follow the proc e dure outline d
b elow to d etermine the sp e cific trouble.
NOTE: A TROUBLE condition reduces the security your system is designed to provide. Call your
installing company for service.

To view troubles from an LED Keypad:

A trouble will b e indic ate d by the Trouble light which will remain O N until the trouble condition is
cle are d. If you c annot d etermine or reme dy the c ause of the trouble condition, conta ct your installer for
assistanc e.
To view the typ e of trouble condition, press [
various trouble conditions:
ZONE LIGHT
TYPE OF TROUBLE
1 ................. Servic e re quire d. Press [1] and one or more of the zone lights corresponding to the
following system troubles will turn O N:
1. Low B attery
2. B ell C ircuit Trouble
3. G eneral System Trouble
4. G eneral System Tamp er
2 ................. Indic ates the loss of A C power. When this trouble oc curs, the Trouble light will turn
O N but the keyp a d buz z er will not sound.
3 ................. Tele phone line trouble.
4 ................. The p anel has faile d to communic ate with the c entral station.
5 ................. Zone fault. Press [5] and the zone light(s) corresponding to the faulted zones will turn O N.
6 ................. Zone tamper. Press [6] and the zone light(s) corresponding to the tamp ere d zones will
turn O N.
7 ................. Low zone b attery. Press [7] and the numb ers corresponding to the zones with
b attery trouble will turn O N.
8 ................. Loss of time on system clock. To set the system time, following the instructions in
"Setting System D ate and Time" on p a g e 13.

To view troubles from an LCD Keypad:

From th e R e a d y st a t e , us e th e arrow ( < > ) k e ys to s croll to th e followin g m e ss a g e .
Press [
System Trouble
(*2) to View< >
Use the arrow (< >) keys to view which troubles are present on the system. O nc e
View Trouble < >
you have scrolle d through the list of troubles, press the [#] key to exit the Trouble
"Trouble Message"
Viewing mod e and return to the Re a dy state.
12
][2]. O ne or more zone lights will turn O N, indic ating the
] [2] to view the trouble. The messa g e will re a d...
5. G eneral System Sup ervisory
6. Not use d
7. P C 5204 Low B attery
8. P C 5204 A C F ailure