ATTO Technology FastStream SC 7700 Technische Daten - Seite 2

Blättern Sie online oder laden Sie pdf Technische Daten für Computer Hardware ATTO Technology FastStream SC 7700 herunter. ATTO Technology FastStream SC 7700 2 Seiten. Atto technology faststream sc-5300 storage controllers: specifications
Auch für ATTO Technology FastStream SC 7700: Broschüre (14 seiten), Heißes Blatt (2 seiten), Handbuch zur Auswahl (1 seiten), Handbuch zur Auswahl (1 seiten), Interoperabilitätsmatrix (1 seiten), Schnellstart-Handbuch (2 seiten)

ATTO Technology FastStream SC 7700 Technische Daten
FastStream™ SC 7700
Storage Controller
Technical Features
RAID Levels
Key Features
Hardware Specifications
Fibre Channel Interface
Management Interface
Management
Setup and Monitoring
Local and Network Management
Environmental & Physical Specifications
Dimensions
Operating Environment
Storage Environment
Power
Airflow
RoHS Compliant
Ordering Information
Model Number
Technical Specification
FastStream SC 7700
©2008 ATTO Technology, Inc. Specifications subject to change without notice.
• JBOD, DVRAID, 0, 1, 4, 5, 6, 10, 40, 50 and 60 plus N-way mirroring
• Tunable RAID Rebuild Priority
• Real-time Performance Metrics
• Application Performance Reporting • Field Upgradeable Firmware
• Local and Global Hot Spares
• Configuration Cloning
• Drive Initialization and Verification
• Partitioning of RAID Volumes
• Port Mapping for LUN Isolation
• 4-Gigabit, auto-negotiates to 2/1 Gigabit devices
• Two Optical SFP (Small Form Factor Pluggable) Fibre Channel Host Ports
• Two Optical SFP Fibre Channel Device Ports
• Full support for direct connect for F-port fabric switches
• Class 3 and Intermix ANSI Fibre Channel Specifications
• PLDA, public loop login (NL-ports) and fabric connect (N-port)
• Full-duplex transmissions
• RJ-45 connector for Ethernet management port
• RS-232 serial header console port
• Simplified one-click setup allows for system setup in just minutes
• Built in read-only drive performance monitoring allows you to gauge
storage performance while host-based applications are in use
• ExpressNAV
TM
storage manager browser-based user interface for remote
configuration, management and diagnostic capabilities
• Local diagnostics supported via CLI, Telnet and FTP
• Command line and menu-based ASCII text management access via the
Ethernet management port
• 1.69" (1U) H x 17.31" W x 9.9" L
• Temperature: 5 - 40° C
Humidity: 10 - 90% non-condensing
• Temperature: -40 - 70° C
• Input: 100-240 VAC, 2.5A, 47-63 Hz
• 11 CFM recommended
• Ambient air not to exceed 40° C
• Yes
FSSC-7700-D00
Power Behind the Storage
• SCSI Enclosure Services (SES)
• Configurable Sector Sizes to 8KB
• Hot Swap with Auto Rebuild
• Battery Backed Event Log
• ECC Protected Memory
• Advanced Error Handling
• One button setups for Audio, Video, IT
Humidity: 5 - 95% non-condensing
For More Information:
www.ATTOTech.com
or to Purchase:
www.ATTOStore.com
(716) 691-1999
Rev 9/08