If the PA FREQ does not match the Exciter TX FREQ, please be sure that the serial
cable is properly connected don each side. You can alternatively bypass the PA
AUTO detection of the Exciter channel FREQ by changing the PA FREQ-TYPE
from AUTO to MANUAL – which will cause a channel frequency pull-down menu
to appear – by which you would manually select the channel frequency that the
exciter is set to. If using the manual approach, please also double check that the PA
(mains STATUS screen) displays the same channel frequency as the Exciter before
proceeding further.
6) Turn the PA RF-Switch to ON on the System Settings tab.
7) The built-in FWD and REF power metering in your Marble PA has already been
calibrated at the factory. The PA's touchscreen and its Web interface both contain
the System Forward and Reflected power meter readings FWD-POW and REFL-
POW. Visit the PA's Web interface and verify that the currents (Cur1 thru 9 are
showing real values and not all 0s.