INSPECTION
Refer to the Exploded View and Cross Sectional View drawings on pages 8 &10.
1. Visually inspect all parts removed during
disassembly for excessive wear or damage.
Replace any damaged or questionable
parts.
2. Pay particular attention to the vanes on
end cover (9) and turbine rotor (13) and
look for cracks, chipping, warping or
excessive wear patterns. Rotor (13) should
fit tightly on to the rotor shaft (19). Replace
any
damaged
Remove any burrs.
3. Also pay particular attention to all gear
teeth looking for cracked or broken teeth
and excessive wear. Check the pinion on
the drive assembly (40) for evidence of
unusual contact patterns resulting from
misalignment or improper engagement.
Remove
any
questionable.
4. Check all bearings are free to rotate and
do not have excessive play between races.
If in doubt replace questionable bearings.
or
questionable
burrs
or
replace
Do not wash shielded bearings that are to be
reused in solvent or blow with compressed air
as
it
Bearings that are to be reused should be
cleaned by wiping the end shields with a
clean cloth.
parts.
5. Clean all other parts that are going to be
reused
solvents.
Ensure cleaning operations are carried out in
a properly vented area away from open
flames.
if
6. It is recommended that when servicing your
AUSTART Turbine Starter always replace
complete repair kit contents.
12
CAUTION
may
remove
internal
with
commercially
WARNING
!
lubrication.
approved