(Continued from page 15)
Trouble 4: AREA OF COVERAGE CHANGES.
CAUSE
A. Customer has reposftoned furniture or equip-
ment in premises.
B. Mounting surface is unstable. A few degrees
vertical shift can change range substantially.
Trouble 5: UNtT DOES NOT APPEAR TO BE OPERATING.
CAUSE
A. Unit hi not receiving power.
REMEDY
Caution customer that changes in layout can
l.
affect coverage. Re-aim or relocate
the
unit
T
according to installation instructions. Be cer-
,/
tain that unit has not been tampered with.
Mount on secure surface.
REMEDY
Check for presence of appropriate input
voltage at terminals
of
unit.
(Nos. 650 and 651 only) Be certain that unit's
battery lead has been moved from its
STORAGE (shipping/storage) POST to its ac-
tive + V.DC POST.
IMPORTANT: Before any equipment is returned to Ademco for service, a Return Authorization Number should
first be obtained from the nearest Ademco Distribution Center.
If it becomes necessary to return a unit for repair, the optical head and reflector assembly within
the unit should be cushioned by surrounding it with soft packing material (such as tissue,
newspaper, foam or plastic bubbles) to protect it from undue stress during shipment. Take care not
to touch the reflector or sensor surfaces.
GENERAL SPECIFICATIONS:
No. 656
No. 651
Physical:
Electrical:
Width:
4-l/16"
(10.3cm)
Height:
51 l/16" (14Scm)
Depth:
2-7/6" (73cm)
Voltage:
96.5V.AC from 1319
Plug-in Transformer
(Supplied)
Current:
0.6A
Standby.
Up to 10 hrs. with built-in
rechargeable 2V lead-acid
cell, 2.5 AH (supplied) (Ac-
cess to battery is at rear of
unit.)
No. 656-6
No. 651-6
(same)
(same)
(same)
6V.DC
No. 65912EX
No. 651.12EX
;:t:r;
(same)
lPV.DC
40 mA
30mA
None built-in. Power source
used should be able to pro-
vide at least 4 hrs. of stand-
by power.
Atann Relay
Contact Rating:
l.OA, 3OV.DC1120V.AC
(same)
(same)
l
CAUTIONS: Use separate No. 1319 transformer supplied. Do not operate other equipment simultaneously from
the same
transformer.
Damage
to the
transformer
and/or
equipment
could
result.
1 Use of a No. 1326 Transformer will damage the equipment.
1
--
90
84