Autonics BWPK Series Produkthandbuch - Seite 3

Blättern Sie online oder laden Sie pdf Produkthandbuch für Zubehör Autonics BWPK Series herunter. Autonics BWPK Series 4 Seiten. Slim plastic single-beam picking sensors

Autonics BWPK Series Produkthandbuch
Specifications
Model
BWPK25-05(P)
Sensing method
Through-beam
Light source
Infrared LED (850 nm modulated light)
Sensing distance
Long / Short mode (switch)
Long mode
0.1 to 3.0 m
Short mode
0.05 to 1.0 m
Sensing target
Opaque material
Min. sensing target
≥ Ø 35 mm
Number of optical axes 5
Sensing height
100 mm
Optical axis pitch
25 mm
Response time
≤ 30 ms
Operation mode
Light ON / Dark ON (switch)
Selection for sensing distance, selection for operation mode, Picking
Functions
indicator ON / flashing
Interference protection Interference protection by transmission frequency selection
Synchronization type
Timing method by synchronous line
Non-contact or contact input
External picking input
NPN open collector output: lighting (0 - 2 V), light out (5 - 30 V or open)
PNP open collector output: lighting (4 - 30 V), light out (0 - 3 V or open)
Indicator
Emitter / receiver: opreation indicator (red, green, yellow)
Approval
ᜢ ᜫ
Weight (packaged)
≈ 180 g (≈ 220 g)
Power supply
12 - 24 VDCᜡ (ripple P-P: ≤ 10 %)
Current consumption
Emitter / receiver: ≤ 60 mA
Control output
NPN / PNP open collector output model
Load voltage
≤ 30 VDCᜡ
Load current
≤ 150 mA
Residual voltage
NPN: ≤ 1 VDCᜡ, PNP: ≤ 2.5 VDCᜡ
Reverse power protection circuit, output short overcurrent
Protection circuit
protection circuit
Insulation resistance
≥ 20 MΩ (500 VDCᜡ megger)
± 240 V the square wave noise (pulse width: 1㎲) by the noise
Noise immunity
simulator
Dielectric strength
1,000 VACᜠ 50 / 60 Hz for 1minute
1.5 mm double amplitude at frequency of 10 to 55 Hz (for 1 min) in
Vibration
each X, Y, Z direction for 2 hours
Shock
500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times
Ambient illum.
Sunlight: 10,000 ㏓, incandescent lamp: 3,000 ㏓
(receiver)
Ambient temp.
-10 to 55 ℃, storage: -20 to 60 ℃ (no freezing or condensation)
Ambient humi.
35 to 85 %RH, storage: 35 to 85 %RH (no freezing or condensation)
Protection rating
IP40 (IEC standard)
Cable spec.
Ø 4 mm, 4-wire, 2 m (emitter: 3-wire)
Wire spec.
AWG 22 (0.08 mm, 60-core), insulator diameter: Ø 1.25 mm
Material
Case: PC / ABS, sensing part: PMMA
Troubleshooting
Malfunction
Cause
Power supply
Cable incorrect connection, or
Non-operation
disconnection
Out of rated sensing distance
Pollution by dirt of sensor cover
Non-operation in
sometimes
Connector connection failure
Out of the rated sensing distance
There is an obstacle to cut off the
Control output is
emitted light between emitter and
OFF even though
receiver.
there is not a target
There is strong electric wave or
object.
noise generator such as motor,
electric generator, or high voltage
line, etc.
Control output line is shorted out.
LED displays for
over current
Over load
Troubleshooting
Supply the rated power.
Check the wiring connection.
Use it within rated sensing
distance.
Remove dirt by soft brush or cloth.
Check the assembled part of the
connector
Use it within the rated sensing
distance.
Remove the obstacle.
Put away the strong electric wave
or noise generator.
Check the wiring connection.
Check the rated load capacity.
Functions
■ Interference protection (transmitted light frequency change)
When you install more than two products, there is a risk of mutual interference.
Change the frequency to prevent this interference.
Set one sensor as frequency A and the other as frequency B via the setting switch.
■ Sensing distance change (Long / Short mode)
This function is to change the product detection distance by mode setting for the
installation environment.
When installing more than 3 sets of products closely, set as Short mode to minimize
mutual interference. Set this function via the setting switch of the emitter.
■ Operation mode change (Light ON / Dark ON)
It is available to select with user's preference.
Set this function via the setting switch of the receiver.
- Light ON: The control output is ON when it is light ON
- Dark ON: The control output is ON when it is light OFF
■ Picking indicator (ON / flashing)
Picking indicator is lighting or flashing to make out work sensing operation more
easily. Set this function via the setting switches of the emitter / receiver.