Aire-Flo 4AC14L48P Installationsanleitung Handbuch - Seite 2
Blättern Sie online oder laden Sie pdf Installationsanleitung Handbuch für Klimagerät Aire-Flo 4AC14L48P herunter. Aire-Flo 4AC14L48P 17 Seiten. 4ac14 series units
FIGURE 1
TABLE 1 – Unit Dimensions
Model Numbers
4AC14LS18P
28-1/4 (724)
4AC14LS24P
28-1/4 (724)
4AC14LS30P
28-1/4 (724)
4AC14LS36P
28-1/4 (724)
4AC14LS42P
28-1/4 (724)
4AC14L48P
28-1/4 (724)
4AC14L60P
32-1/4 (819)
STEP 1 – SETTING THE UNIT
(Continued) – Unit Placement
NOTICE!
Roof Damage!
This system contains both refrigerant and oil. Some
rubber roofing material may absorb oil, causing the
rubber to degrade. Failure to follow this notice could
result in damage to roof surface.
IMPORTANT
This unit must be matched with an indoor coil as specified
in the Engineering Handbook. Coils previously charged
with HCFC-22 must be flushed.
IMPORTANT
Exhaust vents from dryers, water heaters and furnaces
should be directed away from the outdoor unit. Prolonged
exposure to exhaust gases and the chemicals contained
within them may cause condensation to form on the steel
cabinet and other metal components of the outdoor unit.
This will diminish unit performance and longevity
B
A
B
29-1/4 (743)
33-1/4 (845)
37-1/4 (946)
37-1/4 (946)
33-1/4 (845)
37-1/4 (946)
33-1/4 (845)
To prevent personal injury, as well as damage to panels,
unit or structure, observe the following:
While installing or servicing this unit, carefully stow all
removed panels so that the panels will not cause injury
to personnel, objects or nearby structures. Also, take
care to store panels where they will not be subject to
damage (e.g., being bent or scratched).
While handling or stowing the panels, consider any
weather conditions (especially wind) that may cause
panels to be blown around and damaged.
NOTE - An optional Unit Stand-Off Kit (94J45) is available
for this unit. Black high-density polyethylene feet raise unit
off of mounting surface away from damaging moisture.
Four feet are furnished per order number.
Page 2
WARNING
PLACEMENT
INSTALL UNIT AWAY
FROM WINDOWS
TWO 90º ELBOWS INSTALLED IN LINE SET
WILL REDUCE LINE SET VIBRATION
FIGURE 2
FIGURE 3