PULSE METER
MP5M SERIES
I N S T R U C T I O N M A N U A L
Thank you for choosing our Autonics product.
Please read the following safety considerations before use.
Safety Considerations
※Please observe all safety considerations for safe and proper product operation to avoid hazards.
※Safety considerations are categorized as follows.
Warning Failure to follow these instructions may result in serious injury or death.
Caution Failure to follow these instructions may result in personal injury or product damage.
※The symbols used on the product and instruction manual represent the following
symbol represents caution due to special circumstances in which hazards may occur.
Warning
1. Fail-safe device must be installed when using the unit with machinery that may cause
serious injury or substantial economic loss. (e.g. nuclear power control, medical equipment,
ships, vehicles, railways, aircraft, combustion apparatus, safety equipment, crime/disaster
prevention devices, etc.)
Failure to follow this instruction may result in personal injury, fire, or economic loss.
2. The unit must be installed on a device panel before use.
Failure to follow this instruction may result in electric shock.
3. Do not connect, repair, or inspect the unit while connected to a power source.
Failure to follow this instruction may result in electric shock.
4. Do not disassemble or modify the unit. Please contact us if necessary.
Failure to follow this instruction may result in electric shock or fire.
5. Check the terminal numbers before connecting the power source and measurement input.
Failure to follow this instruction may result in fire.
Caution
1. Do not use the unit outdoors.
Failure to follow this instruction may result in electric shock or shortening the life cycle of the unit.
2. When connecting the power input or measuring input, make sure to tighten the terminal
screw bolt above 0.74N•m to 0.90N•m.
Contact failure may result in fire.
3. Use the unit within the rated specifications.
Failure to follow this instruction may result in electric shock or shortening the life cycle of the unit.
4. Do not use loads beyond the rated switching capacity of the relay contact.
Failure to follow this instruction may result in insulation failure, contact failure, contact bonding, relay
damage, or fire.
5. Do not use water or oil-based detergent when cleaning the unit. Use dry cloth to clean the
unit.
Failure to follow these instructions may result in electric shock or fire.
6. Do not use the unit where flammable or explosive gas, humidity, direct sunlight, radiant heat,
vibration, and impact may be present.
Failure to follow this instruction may result in fire or explosion.
7. Keep dust and wire residue from flowing into the unit.
Failure may result in fire or product malfunction.
8. Check the polarity of the measurement input contact before wiring the unit.
Failure to follow this instruction may result in fire or explosion.
Ordering Information
MP 5 M
-
4
N
Main output (Comparative value output)
N
Indicator
Relay single (high-limit) output+
1
NPN open collector output
Output
Relay dual (high/low-limit) output+
2
NPN open collector output
2
24VAC 50/60Hz, 24-48VDC
Power supply
4
100-240VAC 50/60Hz
Size
M
DIN W72×H72mm
Digit
5
99999 (5-digit)
Item
MP Pulse meter
Product Description
1: Display
4
Displays current value in RUN mode.
Alternately displays setting parameters and cor-
responding value in SETTING mode.
2:
key
1
In RUN mode, press the key once to check max./
min. value.
2
In RUN mode, hold the key for over 2 sec to enter
parameter groups.
5
3:
,
key
3
Select parameter groups, and select or setting
values in the corresponding parameters.
4: Output status indicator
5: Thumbwheel switch for HIGH/LOW setting value
※The high-limit setting model(MP5M- 1) does not include the dotted line parts.
※ The above specifications are subject to change and some models may be discontinued
without notice.
Specifications
MP5M-2N
MP5M-4N
MP5M-21
MP5M-41
MP5M-22
Model
Indicator
High-limit setting
High/Low-limit setting
Display method
7-segment LED (zero blanking method)
Character size
W4×H8mm
Display range
-19999 to 99999
AC voltage
100-240VAC
50/60Hz
Power
supply
AC/DC voltage 24VAC
50/60Hz, 24-48VDC
AC voltage
Max. 9VA (100-240VAC
50/60Hz)
Power
consumption
AC/DC voltage Max. 6.5VA (24VAC
50/60Hz), Max. 5W (24-48VDC )
Permissible voltage range 90 to 110% of rated voltage
External power supply
Max. 12VDC
±10% 80mA
·Solid state input 1: Max. 50kHz (pulse width: min. 10㎲)
·Solid state input 2: Max. 5kHz (pulse width: min. 100㎲)
Input frequency
※For F7, F8 operation mode, max. 1kHz (pulse width: min. 500㎲)
·Contact input: Max. 45Hz (pulse width: min. 11ms)
[Voltage Input] High: 4.5-24VDC , Low: 0-1VDC, input impedance: 3.9kΩ
Input method
[No-voltage Input] Short-circuit impedance: Max. 80Ω, Residual voltage: Max. 1VDC,
Open-circuit impedance: Min. 100kΩ
·Operation mode F1, F2, F7, F8
: 0.0005Hz to 50kHz
·Operation mode F3, F4, F5, F6
: 0.01 to max. of each time range
Measurement range
·Operation mode F9, F10, F11, F14
: 0 to 99999
·Operation mode F12, F13
: -19999 to 99999
Measurement accuracy
·Operation mode F1, F2, F7, F8
: F.S.±0.05%rdg±1-digit
(23℃±5℃)
·Operation mode F3, F4, F5, F6
: F.S.±0.01%rdg±1-digit
Display cycle
OFF (for F2, F14 operation mode), 0.05, 0.5, 1, 2, 4, 8 sec (same as update output cycle)
Frequency/Revolutions/Speed (F1), Passing speed (F2), Cycle (F3),
Passing time (F4), Time interval (F5), Time differential (F6), Absolute ratio (F7),
Operation mode
Density (F8), Length measurement 1 (F9), Interval (F10), Accumulation (F11),
Addition/Subtraction-individual input (F12), Addition/Subtraction-phase difference
input (F13), Length measurement 2 (F14)
-9
9
Prescale function
Direct input method (0.0001×10
to 9.9999×10
)
※1
Hysteresis
-
0 to 9999
Relay single
250VAC 3A resistive load 1c -
250VAC 3A resistive load 1a
Main
Relay dual
-
-
×2
output
NPN open
Max. 30VDC
100mA
Max. 30VDC
collector
Memory retention
Non-volatile memory (number of inputs: 100,000 operations)
Insulation resistance
Over 100MΩ (at 500VDC megger)
Dielectric strength
2,000VAC 60Hz for 1 min
Noise immunity
±2kV the square wave noise (pulse width: 1㎲) by noise simulator
Mechanical
0.75mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 1 hour
Vibration
Malfunction
0.5mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 10 min
Mechanical
300m/s² (approx. 30G) in each X, Y, Z direction for 3 times
Shock
Malfunction
100m/s² (approx. 30G) in each X, Y, Z direction for 3 times
Relay
Mechanical
-
Min. 5,000,000 operations
life cycle
Electrical
-
Min. 100,000 operations (250VAC 3A resistive load)
Environ-
Ambient temp. -10 to 50℃, storage: -20 to 60℃
ment
Ambient humi. 35 to 85%RH, storage: 35 to 85%RH
Approval
ᜢ ᜧ
Weight
※2
Approx. 243g (approx. 168g) Approx. 256g (approx. 181g) Approx. 265g (approx. 190g)
※1: Setting range will vary depending on the decimal point.
※2: The weight includes packaging. The weight in parenthesis is for unit only.
※Environment resistance is rated at no freezing or condensation.
Connections
Indicator (MP5M- N)
※1: Operation mode F1 to F10
: Display value HOLD
Operation mode F11 to F14
: Display value RESET
※2:
Model
Source
HOLD/
MP5M-21
INA
INB
+12V
0V
※1
RESET
24-48VDC
MP5M-22
8
9
10
11
12
13
14
24VAC 50/60Hz
MP5M-2N
MP5M-41
100-240VAC
15
MP5M-42
50/60Hz
16
MP5M-4N
17
1
2
3
4
5
6
7
-
+
※2
SOURCE
High-limit setting (MP5M- 1)
High/Low-limit setting (MP5M- 2)
HOLD/
HOLD/
INA
INB
+12V
0V
※1
RESET
High
INA
INB
+12V
0V
RESET
8
9
10
11
12
13
14
8
9
10
11
15
16
17
H
L
1
2
3
4
5
6
7
1
2
3
4
CONTACT OUT:
CONTACT OUT:
250VAC 3A
250VAC 3A
RESISTIVE LOAD
-
+
RESISTIVE LOAD
※2
SOURCE
Dimensions
14.3
MP5M-42
72
11.8
Parameter Groups
Parameter 0 group
RUN
(Max./Min. monitoring value)
mode
2 sec
Parameter 1/2/3 group
※Press the
,
keys to select or set the desired value.
※Press the
key once after changing the setting value, to save the setting value and move to the
next parameter.
※Hold the
key for 1.5 sec at any parameters to return to the select parameter group mode.
※ Hold the
key for 3 sec to save the setting value and return to RUN mode after changing the
setting value.
100mA ×2
※ If there is no key input for 60 sec while setting the parameters, the new settings are ignored, and the
unit will return to RUN mode with previous settings.
※ The dotted line parameters may not appear depending on output specifications or other parameter
settings. Please refer to '
Operation mode by parameter group'.
※1: Each parameter and corresponding setting value will flash alternately every 0.5 sec.
● Parameter 0 group
RUN mode
Flashes
※1
alternately
Max. monitoring
hPEK
99999
value
Min. monitoring
lPEK
`9999
value
● Parameter 1 group
2 sec
RUN mode
PARa1
3 sec
Flashes
※1
alternately
Operation mode
MODE
F1
●Setting range: F1 to F14
IN-A
NPnhF
Sensor type of
input A
Sensor type of
IN-B
NPnhF
input B
Output mode
●Setting range
OUT-T
STARD
Parameter Output mode Parameter Output mode
STARD S (Standard)
OUT-H H (High)
OUT-L L (Low)
※ Only appears in high/low-limit setting model.
Output hysteresis
●Setting range: 0000 to 9999
HYS
0001
(
the setting range varies depending on the decimal point setting
※ Only appears in high-limit setting models,
high/low-limit setting models.
L comparative output
GUARD
fDEFY
※Only appears in high/low-limit setting models.
※1
High Low
STArT
12
13
14
Start compensation timer function & compensation time
●Setting range: )0 to 9(9(sec)
※ Only appears in high/low-limit setting models.
15
AUToA
999(9
Auto-zero time for input A
16
17
AUToB
999(9
Auto-zero time for input B
5
6
7
Memory retention
MEMO
OFF
●Setting range: ON, OFF
-
+
※2
SOURCE
Panel Cut-out Dimensions
75
Min. 91
68
0.7
0
● Parameter 2 group
Terminal
2 sec
input
RUN mode
11-12
HOLD/RESET
3 sec
Input
Flashes
※1
alternately
DOT
00000
※ Operation mode F1 to F10
: Display value HOLD
Operation mode F11 to F14
3 sec
: Display value RESET
tUNT
tSEC
Time unit and range
PScaH
^0000
PScaY
10 01
PScbH
^0000
PScbY
10 01
Resetting monitoring value
: Hold the
key for over 2 sec.
(reset current value)
DISpT
99999
COUnB
● Parameter 3 group
2 sec
PARa2
PARa3
RUN mode
Flashes
※1
alternately
LOC
●Setting range
3 sec
Parameter Input sensor type
NPnhF NPN solid state input 1
NPnmF NPN solid state input 2
Operation Mode By Parameter Groups
NPnlF NPN contact input
PNphF PNP solid state input 1
Operation
F1
F2
F3
F4
mode
PNpmF PNP solid state input 2
Parameter
PNplF PNP Contact input
hPEK
0 group
lPEK
MODE
IN-A
OUT-B B (Block)
※1
IN-B
OUT-I I (One-shot)
※2
OUT-T
OUT-F F (Deflection)
※1
1 group
HYS
GVARD
AVToA
)
AVToB
MEMO
DOT
limit
tUNT
PScaH
9(9
PScaY
2 group
PScbH
PScbY
※5
DISpT
COUnB
3 group
LOC
● Setting range:
※1: Only appears in high/low-limit setting models.
)1 to 999(9(sec)
※2: Only appears in high-limit setting models, high/low-limit setting models.
※3: The settings for IN-B and IN-A are applied.
※4: ( ) F output mode[OUT-F] cannot be set.
※5: ( ) setting range: OFF, )05, )5, 1, 2, 4, 8
Monitoring delay function by output mode
Output mode
S mode
Parameter
STARD
Comparative output limit
Start compensation timer
(unit: mm)
Bracket
8.3
7.3
46
4
PARa1
PARa2
PARa3
Decimal point location of display value
●Setting range: 00000, 000)0, 00)00, 0)000, )0000
●Setting range
99(99
tSEC (sec)
tMIN (min)
999.99s
999.99m
99(99
99(99
tMIN
99(99
999(9
9999.9s
999(9
9999.9m
99999
99999s
99999
99999m
Prescale mantissa (X) of input A
●Setting range: )0001 to (9999
Prescale exponent (y) of input A
-9
9
●Setting range: 10 - 9 (10
) to 10 09 (10
)
Prescale mantissa (X) of input B
●Setting range: )0001 to (9999
Prescale exponent (y) of input B
●Setting range: 10 - 9 (10
-9
) to 10 09 (10
9
)
Display cycle of measurement value
●Setting range: )05, )5, 1, 2, 4, 8 (sec)
)05
※ Setting range in operation mode F2, F14
: OFF, )05, )5, 1, 2, 4, 8 (sec)
Setting value of Input B
●Setting range: 1 to 99999
PARa1
PARa2
PARa3
Parameter Function
OFF
Unlock
Lock
OFF
Locks all
LOc0
●Setting range:
Parameter 1, 2, 3 lock
LOc1
LOc2
Parameter 2, 3 lock
LOc3
Parameter 3 lock
( : parameter display,
X: no parameter display)
F5
F6
F7
F8
F9
F10
F11
F12
F13
F14
Appears in all operation modes(F1 to F14).
※3
※4
Appears in all operation modes(F1 to F14).
H mode
L mode
B mode
I mode
F mode
OVT-;
OVT-L
OVT-B
OVT-I
OVT-F