Emergency Procedures
In the unlikely event that the WaterCop® Classic System should shut off the main
water supply and then become inoperable due to a power outage or damage, it is
possible to manually operate the WaterCop® to return water service . Unplug the
WaterCop® from its power source . The valve may be manually opened by removing
the clip holding the housing to the valve, sliding the housing off the valve shaft, and
turning the valve shaft a quarter turn with a screwdriver . This procedure should only
be necessary in emergencies .
Relay Wiring Diagram WaterCop
CAT5 E CABLE
WATERCOP RJ45
12 VDC POWER SUPPLY
192168.02
WARNING
RELAY COIL WILL BE ENERGIZED WHEN THE VALVE CLOSES
Make connections to the relay coil before energizing the actuator.
CONNECT RELAY WIRES (12 VDC)
TO COIL TERMINALS A & B.
GREEN/WHITE
ORANGE
+
12 VDC
+
120 VAC
Classic
®
WPRLY RELAY &