Autopilot APCECOD Handbuch - Seite 5

Blättern Sie online oder laden Sie pdf Handbuch für Controller Autopilot APCECOD herunter. Autopilot APCECOD 17 Seiten. Deluxe digital co2 controller

Page 4

Error LEDs

The APCECOD is smart enough to monitor the CO2 conditions
and to alert the user to a problem with the device connected to
the APCECOD. Here is how it works.
As the unit functions normally, the CO2 level will be slowly but
steadily changing. These small changes are detected by the
controller.
If the controller does not detect a slight change in the CO2 level
within a 1-hour period, the unit will de-activate the CO2 output
and the green Error LED will be flashing to indicate the CO2
device may have a problem.
This safety feature is extremely important and useful to
eliminate "runaway" conditions which could result in crop damage
or other more serious problems.
If the Error LEDs are blinking, the user should check the CO2
device and remote sensor for proper function.
Note:
To reset an error, press the Enter / reset button.
APCECOD