INSTRUCTION MANUAL
3. Circulating pump: A
circulating pump will
constantly supply water
to the sensor sampling
assembly. The pump
includes an inlet filter to
ensure the sensors do
not become fouled. The
circulating pump will also
provide good aeration
of the water while
operating.
4. Dosing pump: A
chemically resistant
low-voltage peristaltic
pump is used to
accurately transfer the pH
adjustment liquid (acid or
alkali) into the water. The
pump comes with a low-
volt power supply.
5. controller: The APCEPH1
controller is the "brain"
of the system. The
sensors and peristaltic
pump connect to the
controller.
 
3. suBMersiBle
circulatinG
puMp*
 
*Sold separately
4. peristaltic
DosinG
puMp
pH
adjustment
liquid inlet
5. controller
LCD
display
4 simple
to operate
push
buttons
Dosing
pump
connection
 
 
pH
adjustment
liquid outlet
3