For the indispensable introduction of fresh air in the room, a
similar opening of at least 100 cm
provided at a height near floor level so as not to be obstructed on
the inside or outside of the wall and not to hinder the correct
combustion of the burners and the regular extraction of vitiated
air, and with a height difference of at least 180 cm with respect to
the outlet opening.
The quantity of air necessary for combustion must not be less
3
than 2 m
/h for every kW of power (see total power in kW on the
appliance rating plate).
In all other cases, when there are other appliances in the same
room, or when direct natural ventilation is not possible and
indirect natural ventilation of forced ventilation has to be created,
contact a qualified specialist for carrying out installation and
preparing the possible ventilation system in strict compliance with
current regulations.
Flues already used by other appliances must not be used for
exhausting combustion products.

Electrical connection

Before connecting the appliance, make sure that:
1. the house electrical power supply nominal voltage matches that of the appliance, as given on the rating plate;
2. the power supply line to which the appliance is connected is of adequate power with respect to the
max. power absorbed by the appliance, as given on the rating plate;
3. the house electrical system has a correct grounding system.
• An omnipolar switch with a distance of at least 3 mm between contacts must be installed.
NB: After installation, the electrical components must only be accessible with the use of a special tool.
The power cord must be of the H05RR-F type, in compliance with the table given below.
POWER SUPPLY VOLTAGE
1N ~ 230 V
Instructions for the installer
Instructions
• Disconnect the power plug and close the gas tap before carrying out any repairs or
operation.
• The qualified technician is responsible for correct installation according to current safety
regulations.
• Grounding of the appliance is compulsory by law.
The Manufacturer declines any responsibility for possible damage to persons, animals or things due to
non-compliance with the above mentioned regulations. The technical data is given on the rating plate
located on the inside of the drawer door. The adjustment conditions are given on a label applied on the
packing. Do not use the oven door handle grip for handling operations, or for removing the appliance
from the packing.
The appliance is in class 1.
2
directly to the outside must be
NUMBER OF WIRES x DIMENSIONS
3 x 1.5 mm²
21