Afriso EURO-INDEX Unimes E Betriebsanleitung - Seite 13

Blättern Sie online oder laden Sie pdf Betriebsanleitung für Messgeräte Afriso EURO-INDEX Unimes E herunter. Afriso EURO-INDEX Unimes E 20 Seiten. Mechanical tank contents gauge with electronic remote indication

6.5
Connecting the direct indication gauge and the remote indi-
cator
6.6

Connecting the battery of the remote indicator

Unimes E
1.
Adjust the length of the float wire to the tank height according to
the illustration below:
2.
Hold the float wire in this position.
3.
Turn the adjustment screw to set the pointer to zero.
The direct indication gauge is now adjusted to the tank.
Plug the connector of the connection cable into the rear side of
the direct indication gauge.
1.
When the direct indication gauge and the remote indicator are
electrically connected, open the housing of the remote indicator
by turning the upper part all the way to the stop and pulling it
open.
Mounting and commissioning
Height of flange
1
connection piece
Fixed lead seal
2
Ø or height
3
13