Fujitsu Primergy RX100 S4 Handbuch für Service-Ergänzungen - Seite 25

Blättern Sie online oder laden Sie pdf Handbuch für Service-Ergänzungen für Server Fujitsu Primergy RX100 S4 herunter. Fujitsu Primergy RX100 S4 43 Seiten.
Auch für Fujitsu Primergy RX100 S4: Start Handbuch (8 seiten)

Fujitsu Primergy RX100 S4 Handbuch für Service-Ergänzungen
Replacement routines
4.7

Replacing the processor

V
CAUTION!
Processors are modules which are extremely sensitive to electrostatic
discharges and therefore must always be handled with care. After a
processor has been removed from its protective sleeve or from its socket,
place it with its smooth side down on a non-conducting, antistatic
surface. Never push a processor over a surface.
Ê Open the server as described in the
Figure 9: Removing the ventilation duct
Ê Remove the ventilation duct over the heat sink.
Ê Loosen the four screws in a crossover pattern.
Ê Loosen the heat sink by turning it back and forth and then lift it out.
Ê Remove the residual thermal paste from the underside of the heat sink.
Ê Clean the underside of the heat sink using a lint-free cloth.
RX100 S4
section "Preparation" on page
Service Supplement
Replacing the processor
17.
25