Default: JP24 is closed; JP3, JP4, JP5 and JP35 are open
By default, the external reset is enabled and set to immediate reset, the reset by UART is
disabled.
Note:
While a reset signal is asserted the red Reset-LED D14 is lit.
During normal operation, this LED should be off!
If JP35 (Polarity) is set, JP4 and either JP3 or JP5 have to be set, too.
If the reset LED is steadily on, check the power supply input voltage and the settings for the
reset-generation by UART.
3.10 Buttons SW1, SW2, SW3, SW4, SW5, SW6 (JP: 12, 14, 16, 20, 23, 24)
JP12, JP14, JP16, JP20, JP23
Five user push buttons SW1-SW5 can be connected to the microcontroller.
JP24
External reset circuit and button SW6 can be connected to the microcontroller.
Jumper
Setting
Closed
JP12 (SW1)
Open
Closed
JP14 (SW2)
Open
Closed
JP16 (SW3)
Open
Closed
JP20 (SW4)
Open
Closed
JP23 (SW5)
Open
Closed
JP24 (Reset)
Open
Default: JP12, JP14, JP16, JP20, JP23, JP24 = Closed
By default, all push-buttons as well as the reset circuit are connected to the microcontroller.
© Fujitsu Microelectronics Europe GmbH
SK-91464A-100PMC User Guide
Chapter 3 Jumpers and Switches
Description
Pin 74 (INT0) of the MCU is connected to "SW1"
No connection to the microcontroller
Pin 77 (INT1) of the MCU is connected to "SW2"
No connection to the microcontroller
Pin 53 (ATGX) of the MCU is connected to "SW3"
No connection to the microcontroller
Pin 2 (ICU0/TIN0) of the MCU is connected to "SW4"
No connection to the microcontroller
Pin 4 (ICU2/TIN2) of the MCU is connected to "SW5"
No connection to the microcontroller
INITX is connected to the reset IC and SW6