2 Installation
Carefully remove the board from the shipping carton.
First, check if there are any damages before powering up the evaluation board.
For the power supply a DC input voltage of 9V – 12V is recommended. The positive
voltage (+) must be connected to the shield, and ground (GND) must be connected to
the center pin of the connector X12!
Special care must be taken to the max. input voltage, if the LIN Vs lines are supplied
by the board (JP44/JP45), since the input supply voltage is directly applied to pin 1 of
X6 / X8 without a voltage regulator.
After power-on, the green power-on LEDs (D16, D17, D18) should be lit. If the LEDs do not
light up, switch off the power supply and check input polarity and the settings of JP43, JP29,
JP30 and JP37.
The in-circuit programming allows the user to program own applications into the Flash
memory. The procedures for Flash programming are described in chapter 4.
If the board shall be used as an emulator target board, switch off the power supply and
remove the microcontroller from the socket. Now the probe cable can be mounted on the
socket. Take care of the pin 1 marking on the socket and fasten the probe cable with the
provided screws.
Do not use any other probe cable than MB91464A-NLS-100PMC only!
Connect the probe cable to the MB2198-300 emulation Adapter Board. Check all jumper
settings of the evaluation board (especially JP29 and JP30), the Probe Cable and the
Adapter Board.
When turning on the system, be sure to use the following power-up sequence:
1. Power up the Emulator Main Unit (MB2198-01)
2. Power up the Adapter Board (MB2198-300)
3. Power up the target Board (SK-91464A-100PMC)
To turn off the system, switch off the components in reverse order, beginning with the target
Board.
Please refer to the corresponding user manuals and application notes for the emulator how
to set up the emulator system. After power on, the 'Reset'-LED of the emulator must be off
and the 'Vcc'-LED must be on.
If the Reset LED is still lit, check the DIP-switch settings of the emulator system and the
power supply of the evaluation board.
Note:
Some customers experience connectivity problems when connecting the MCU into
the socket adapter. Only the small red screwdriver available in your box should be
used to connect the cover (HQPACK) onto the socket (NQPACK).
If the four screws are not tightening equally, then it may cause a poor contact.
Do not screw the cover too tight (max 0.054 Nm). If you have connectivity problems
then please loosen the screws and tighten again the screws equally.
Do not clean NQPACK, YQPACK, and YQSOCKET with steam. Cleaning material will
contaminate inside of connector.