condition may be checked.
• Is shorter than 1500 mm.
• Fits firmly into place at both ends, where it will
be fixed using clamps that comply with current
regulations.
! If one or more of these conditions is not fulfilled
or if the cooker must be installed according to the
conditions listed for class 2 - subclass 1 appliances
(installed between two cupboards), the flexible steel
hose must be used instead (see below).
Connecting a flexible jointless stainless steel pipe
to a threaded attachment
Make sure that the hose and gaskets comply with
current national legislation.
To begin using the hose, remove the hose holder on
the appliance (the gas supply inlet on the appliance is
a cylindrical threaded 1/2 gas male attachment).
! Perform the connection in such a way that the hose
length does not exceed a maximum of 2 metres,
making sure that the hose is not compressed and does
not come into contact with moving parts.
Checking the tightness of the connection
When the installation process is complete, check the
hose fittings for leaks using a soapy solution. Never
use a flame.
Adapting to different types of gas
It is possible to adapt the appliance to a type of gas
other than the default type (this is indicated on the
rating label on the cover).
Adapting the hob
Replacing the nozzles for the hob burners:
1. Remove the hob grids and slide the burners off their
seats.
2. Unscrew the nozzles using a 7 mm socket spanner
(see fi gure), and replace them with nozzles suited to the
new type of gas (see Burner
and nozzle specifi cations table).
3. Replace all the components
by following the above
instructions in reverse.
Adjusting the hob burners'
minimum setting:
1. Turn the tap to the minimum position.
2. Remove the knob and adjust the regulatory screw,
which is positioned inside or next to the tap pin, until
the flame is small but steady.
! If the appliance is connected to a liquid gas supply,
the regulatory screw must be fastened as tightly as
possible:
3. While the burner is alight, quickly change the position of the
knob from minimum to maximum and vice versa several times,
checking that the flame is not extinguished.
! The hob burners do not require primary air adjustment.
! After adjusting the appliance so it may be used with a different
type of gas, replace the old rating label with a new one that
corresponds to the new type of gas (these labels are available
from Authorised Technical Assistance Centres).
! Should the gas pressure used be different (or vary slightly) from
the recommended pressure, a suitable pressure regulator must
be fitted to the inlet hose in accordance with current national
regulations relating to "regulators for channelled gas".
Replacing the Triple ring burner nozzles
1. Remove the pan supports and lift the burners out of their housing.
The burner consists of two separate parts (see pictures).
2. Unscrew the nozzles using a 7 mm socket spanner. Replace the
nozzles with models that are configured for use with the new type of
gas (see Table 1). The two nozzles have the same hole diameter.
3. Replace all the components by completing the above operations in
reverse order.
• Adjusting the burners' primary air :
Does not require adjusting.
• Setting the burners to minimum:
1. Turn the tap to the low flame position.
2. Remove the knob and adjust the adjustment screw, which is
positioned in or next to the tap pin, until the flame is small but
steady.
3. Having adjusted the flame to the required low setting, while the
burner is alight, quickly change the position of the knob from
minimum to maximum and vice versa several times, checking that
the flame does not go out.
GB