Blättern Sie online oder laden Sie pdf Anleitung verwenden für Server Dell PowerEdge C6100 herunter. Dell PowerEdge C6100 48 Seiten. Poweredge series
Auch für Dell PowerEdge C6100: Portfolio-Handbuch (27 seiten)
2 Start the firmware update through TFTP by typing the appropriate command.
For example:
ipmitool -H 192.168.1.1 -U root -P root raw 0x08 0x01 0x01 0x00
0x01.
The response is 48 (task ID).
Running Virtual Media
The console redirection feature gives the managed server access to media connected to a remote
system on the network. The combination of virtual media and console redirection enables
administrators to perform tasks on the server without being physically present.
The two virtual media types are:
•
Optical Drive—Includes CDROM and ISO image files.
•
Floppy Drive—Includes diskette/USB drives and diskette images.
For each media type, you can virtualize one drive at a time. This may require that you disconnect
media before connecting to a different source.
NOTE:
You must have Access Virtual Media permission to virtualize or disconnect a drive.
Connecting and Disconnecting Virtual Media
Connect to media through the Device menu in the JViewer ( see"Console Redirection" for
directions for accessing the JViewer). Check the box next to the applicable media type(s).
If you are connecting to a diskette or ISO image, either browse to or enter the path where the image
file resides on your system.
NOTE:
Virtual device drive letters on the managed server do not correspond to physical drive letters on
the management station.
To disconnect media, deselect the applicable checkbox.