This section lists the Z9432F-ON switch specifications.
CAUTION:
Operate the product at an ambient temperature not higher than 45°C (113°F).
NOTE:
For RoHS information, see
Topics:
•
Chassis physical design
Chassis physical design
Table 1. Chassis physical design
Parameter
Height
Width
Depth
Chassis weight with factory-installed components
Rack clearance required
Table 2. Environmental parameters
Parameter
Operating temperature
Operating humidity
Storage temperature
Storage humidity
Maximum thermal output
Maximum operational altitude
Maximum nonoperational altitude
Shock
Acoustics
Restricted Material
Compliance.
Specifications
43 mm (1.693 inches)
438.5 mm (17.26 inches)
550 mm (21.65 inches)
● PSU handle 29.3 mm (1.15 in)
● PSU latch 34.6 mm (1.37 in)
● Fan tray handle 25 mm (0.99 in)
● 11.78 kg (2 PSUs and 7 fans)
● 25.97 lbs (2 PSUs and 7 fans)
● Front: 12.7 cm (5 inches)
● Back: 12.7 cm (5 inches)
Specifications
0°C–45°C (32°F–113°F) continuously
5% – 90% (RH), noncondensing
-40°C–70°C (-40°F – 158°F)
5% to 90%, noncondensing
1362 W = 4647.3 BTU/Hr
3,048 meters (10,000 ft)
10,668 meters (35,000 ft)
Dell EMC Spec SV0115 (108000336_REV_25)
Front-to-back fan direction:
● 25C idle @ 30% duty cycle, 7.1 bels
Specifications
NOTE:
Reduce maximum temperature by 1°C/125 meters
(1°F/228 ft) above 950 meters (3,117 ft).
4
Specifications