Installation
Installing the drain hose (sink, gully)
^ See illustration, front view.
,
If you want to drain the
condensed water into a sink, secure
the hose carefully, e.g. by tying the
hose to the water faucet, to avoid
water damage.
^ Use the curved guide to prevent the
drain hose from becoming kinked
(see "Front view" illustration).
Special Installation
,
In special installation
circumstances, the non-return
valve must be installed. Water
flowing back from the dryer can
cause damage.
Special Installations are:
– Connection to a sink standpipe (see
example)
– Miscellaneous connections where
additional appliances like a washer
or dishwasher are connected also.
Example: Connection to a standpipe
The drain hose can be connected to a
special sink standpipe.
^ Remove the adapter and the hose
clamp from behind from the lower
rear side of the dryer.
36
1 Adapter
2 Sink coupling nut
3 Hose clamp
4 Hose extension (Accessory)
5 Non-return valve (Accessory)
6 Dryer drain hose
^ Fit the adapter, 1, to the stand pipe
using nut, 2. If this nut is sealed with
a flat disc, take the disc out.
^ Attach the end of the hose to the adap-
ter 1 and secure the hose clamp 3.
,
The non-return valve 5 must be
installed with the arrow pointing in
the direction of the water flow (see
illustration), otherwise it will not work
properly.
^ Install the non-return valve 5 at the
dryer drain hose 6, see illustration.
^ Secure the non-return valve firmly
with the hose clamp (accessory).