All electrical work must be carried out
by a suitably qualified and competent
person in strict accordance with current
local and national safety regulations.
Connection must be made via a
switched socket. This will make it easier
for service technicians should the
appliance need to be repaired. The
electrical socket must be easily
accessible after installation.
Danger of injury!
Miele cannot be held liable for
unauthorised installation,
maintenance and repair work as this
can be dangerous to users.
Miele cannot be held liable for
damage or injury caused by incorrect
installation, maintenance or repair
work, or by an inadequate or faulty
earthing system (e.g. electric shock).
If the plug has been removed or the
connection cable is not supplied with
a plug, the cooktop must be
connected to the mains supply by a
suitably qualified electrician.
If the appliance is to be hard-wired,
an additional means of
disconnection must be provided for
all poles in accordance with the
wiring rules. When switched off,
there must be an all-pole contact
gap of at least 3 mm in the switch
(including switch, fuses and relays).
Connection data is shown on the
data plate. It must match the mains
electrical supply.
After installation, ensure that all
electrical components are shielded
and cannot be accessed by users.

Electrical connection

Connection
AC 230 V, 50 Hz
The voltage and rated load are given on
the data plate. Please ensure these
match the household mains supply.
Residual current device
For extra safety, it is advisable to
protect the appliance with a suitable
residual current device (RCD) with a trip
range of 30 mA.
Replacing the mains
connection cable
Danger of electrical shock!
The mains connection cable must be
replaced by a suitably qualified and
competent person in accordance
with current local and national safety
regulations.
If the mains cable needs to be replaced,
it must be replaced with a special
connection cable, type H 05 VV-F (PVC
insulated), available from Miele, by a
Miele approved service technician or
suitably qualified electrician in order to
avoid a hazard.
The connection data is given on the
data plate.
15