TROUBLESHOOTING
If the pump operates in a strange manner, immediately turn it off and carefully read the troubleshooting section
below:
APDS Series (for delivery)
Symptom
The liquid is not delivered at all.
The delivery rate is very low.
The drum can is deforming.
APDQS Series (for collection)
Symptom
There is no suction at all.
The suction rate is very low.
The drum can is deforming.
Make sure that...
The compressor is properly connected to the pump.
⚫
The drum can is tightly closed.
⚫
The drum can and the hose are not damaged.
⚫
The valves have been opened.
⚫
The pressure inside of a drum can is not too low.
⚫
(Original setting: 0.5~0.6 kgf/cm2)
Compressed air's pressure is not too low.
⚫
The valves are all max opened.
⚫
Liquid's viscosity is not too high.
⚫
The P-cock is closed.
⚫
The pressure inside of a drum can is not too high.
⚫
(Original setting: 0.5~0.6 kgf/cm2)
The drum is durable enough (refer to safety
⚫
precautions).
Make sure that...
The compressor is properly connected to the pump.
⚫
The drum can is tightly closed.
⚫
The valves have been opened.
⚫
The drum can and the hose are not damaged.
⚫
The hose and the nozzle are not clogged.
⚫
The drum is durable enough (refer to safety
⚫
precautions).