If the below Case Happens ...
1. Do not inhale
● Is a compressor working?
● Is an air hose firmly connected?
● Is an air valve opened?
● Is a pail can deformed or crushed?
● Is a pail can full with collected materials/liquid?
● Is a filter clogged?
2. Low inhalation
● Is an air hose specified size? (More than 3/8)
● Is the air pressure low? (0.4-0.6Mpa)
● Is air leaking from the can?
(The cleaner should fit on a pail can perfectly. Are there any scratches
or dents on the pail?)
● Is the hose or suction port clogged with collected material?
● Is the air valve fully open?
● Is the hose or nozzle damaged?
● Is the viscosity of the liquid too high?
● Is the acoustic material of the silencer clogged?
● Is air leaking from swivel?
● Is the compressor HP sufficient? (3.75KW)