If detachment of valve should be necessary, turn lid clockwise to full stop. Hold the pro-
tecting ring in a firm grip. Turn the attachment. Nut on the inside of the suit by hand or
use tool.
Disassembly (only service technician)
Insert a small screwdriver in the slot of the lid opposite of the + arrows and pry the lid
off. Note for the reassembly the three fingers of the retainer coming up through the ad-
justment lid.
Place valve horizontal and turn the adjustment ring counter clockwise until the adjust-
ment lid with spring and spring ring can be removed. Keep the piston including centre
guide inside its cavity steady while turning the valve upside down. Be careful not to drop
the piston onto hard surfaces. Beware that it's edge is sensitive to damage. The valve
body can now be put aside. Lift the piston carefully and place it with the edge upwards
together with the centre guide on the table.
The membrane and the check valve can now be cleaned from sediments and debris by
flushing the open valve under a tap. Flush thoroughly with warm fresh water. Avoid ma-
king the filter wet by removing it prior flushing. Insert a tool into the openings and gently
pry and evenly to avoid braking the barbs on the filter lid.
ATTENTION: Disassembly should not be made without adequate training and access
too appropriate testing device and tools
Reassembly
Place the Piston (5) gently over the Spikes on the Guide Sleeve (7). Make sure not to
harm the Piston's edge. Insert the Centre guide, small end facing upwards. Place the
Adjustment Lid (11) with spring and spring Ring on top of the Centre Guide (13). Make
sure that the three fingers of the Retainer (10) come up through the designated slots
in the Adjustment Lid (11) while pressing it (11) down with one finger and turning the
Adjustment Ring (12) counter clockwise until it comes to a full stop.
Match the stop tab in the Lid (1) with the corresponding slot in the Adjustment Ring (12).
Align the two Parts and maintain a firm grip with one hand while firmly
pressing together on the opposite side using the other hand.
Use attachment tools or follow these directions:
Hold the Protecting Ring (2) in a firm grip. Turn the Attachment Nut (4) on the inside
of the suit by hand until you feel that it is firmly tightened. The Anti Friction Washer (3)
should always be used, between the Attachment Nut and the inside of the suit.
NOTE! Do not turn the Cover (1) to tighten the valve.