Siemens SITRANS LVL100 Betriebsanleitung - Seite 8

Blättern Sie online oder laden Sie pdf Betriebsanleitung für Schalter Siemens SITRANS LVL100 herunter. Siemens SITRANS LVL100 33 Seiten. Vibrating switches
Auch für Siemens SITRANS LVL100: Betriebsanleitung (32 seiten), Betriebsanleitung (32 seiten), Betriebsanleitung (32 seiten)

Siemens SITRANS LVL100 Betriebsanleitung
Functional principle
Voltage supply
Packaging
Transport
Transport inspection
8
It functions even under difficult conditions such as turbulence, air bub-
bles, foam generation, buildup, strong external vibration or changing
products.
Function monitoring
The electronics module of SITRANS LVL100 continuously monitors
via frequency evaluation the following criteria:
Strong corrosion or damage on the tuning fork
Loss of vibration
Line break to the piezo drive
If a malfunction is detected or in case of power failure, the electronics
takes on a defined switching condition, i.e. the output is open (safe
condition).
The tuning fork is piezoelectrically energised and vibrates at its me-
chanical resonance frequency of approx. 1100 Hz. When the tuning
fork is submerged in the product, the frequency changes. This change
is detected by the integrated electronics module and converted into a
switching command.
SITRANS LVL100 is a compact instrument, i.e. it can be oper-
ated without external evaluation system. The integrated electronics
evaluates the level signal and outputs a switching signal. With this
switching signal, a connected device can be operated directly (e.g. a
warning system, a pump etc.).
The data for power supply are specified in chapter "Technical data".
3.3

Adjustment

The switching status of SITRANS LVL100 can be checked with
closed housing (signal lamp). Products with a density > 0.7 g/cm³
(0.025 lbs/in³) can be detected.
3.4
Storage and transport
Your instrument was protected by packaging during transport. Its
capacity to handle normal loads during transport is assured by a test
based on ISO 4180.
The packaging of standard instruments consists of environment-
friendly, recyclable cardboard. For special versions, PE foam or PE
foil is also used. Dispose of the packaging material via specialised
recycling companies.
Transport must be carried out in due consideration of the notes on the
transport packaging. Nonobservance of these instructions can cause
damage to the device.
The delivery must be checked for completeness and possible transit
damage immediately at receipt. Ascertained transit damage or con-
cealed defects must be appropriately dealt with.