Sony XC-ST30 Technisches Handbuch - Seite 23

Blättern Sie online oder laden Sie pdf Technisches Handbuch für Digitalkamera Sony XC-ST30 herunter. Sony XC-ST30 30 Seiten. Black-and-white video camera module
Auch für Sony XC-ST30: Spezifikationen (4 seiten), Benutzerhandbuch (31 seiten), Produkthandbuch (2 seiten), Technisches Handbuch (31 seiten), Handbuch (4 seiten)

Sony XC-ST30 Technisches Handbuch
External sync input/output
HD/VD (2 to 5 Vp-p)
VS (Sync level: 0.3 Vp-p+0.3V )
* Automatically selected
according to the existence of an
input signal when the HD/VD
signal input/output switch on the
rear panel is set to EXT.
Allowable frequency deviation of external
synchronization
± 1 % (in horizontal synchronous
frequency)
Jitter
Within ± 20 nsec
Scanning system 2:1 interlaced
Non-interlaced (during external
sync input)
Horizontal resolution
XC-ST51/ST50/ST30:
570 TV lines
XC-ST51CE/ST50CE/ST30CE:
560 TV lines
Sensitivity
XC-ST51/ST51CE:
400 lx F11 (r=ON, 0 dB)
XC-ST50/ST50CE:
400 lx F8 (r=ON, 0 dB)
XC-ST30/ST30CE:
400 lx F5.6 (r=ON, 0 dB)
S/N ratio
XC-ST51/ST50:
60 dB
XC-ST51CE/ST50CE:
58 dB
XC-ST30/ST30CE:
56 dB/54 dB
Minimum illuminance
XC-ST51/ST51CE:
0.2 lx (F1.4, AGC ON)
XC-ST50/ST50CE/ST30/ST30CE:
0.3 lx (F1.4, AGC ON)
Gain
A (Auto)/F (Fix)/M (Manual)
(Can be selected using the
GAIN switch on the rear panel.)
Gamma correction
ON/OFF (Can be selected using the
γ compensation ON/OFF switch
on the rear panel.)
Electronic shutter
XC-ST51/ST50/ST30: 1/100 to 1/10,000 seconds
XC-ST51CE/ST50CE/ST30CE: 1/120 to 1/10,000
seconds
XC-ST51/ST51CE
XC-ST50/ST50CE
XC-ST30/ST30CE
External trigger shutter
XC-ST51/ST50/ST30:
1/4 to 1/10,000 seconds
XC-ST51CE/ST50CE/ST30CE:
1/4 to 1/8,000 seconds
* Set using the DIP switch on the rear panel, or
continuously variable with the trigger pulse
width.
Supply voltage
+12 VDC (+10.5 V to 15V)
Power consumption
XC-ST51/ST51CE/ST50/ST50CE:
2.0 W
XC-ST30/ST30CE:
1.9 W
Operating temperature
–5 °C to +45 °C
Storage temperature
–30 °C to +60 °C
Performance assurance temperature
0 °C to +40 °C
Operating humidity
20 to 80 % (Non-condensing)
Storage humidity 20 to 95 % (Non-condensing)
Vibration resistance
10G (For 20 minutes in the X, Y,
and Z directions at 20 to 200
Hz)
Shock resistance 70G
Outside dimensions
44(W) × 29(H) × 57.5(D) mm
Weight
110 g
Standards
UL6500, FCC Class B Digital
Device, and CE (EN61326)
Other
Restart/Reset function
Frame or field integration can be
selected.
Conforms to new 12-pin EIAJ
assignment.
Accessories
Lens mount cap (1)
Operating Instructions (1)
External synchronization for each mode
Mode
Internal sync
Normal
Normal shutter
Mode 1
Trigger signal
generates an
Mode 2
internal VD
(single) signal.
×
Restart/Reset
Specifications
External sync
HD/VD
VS
×
×
×
×
: Can be used.
×
: Cannot be used.