Installation

Fitting the lens

1
Remove the lens mount cap.
2
Screw in the lens (not supplied), and turn it until it
is secured.
Note
Clean the optical filter with a commercially available
blower brush to remove dust.

Using a tripod

To use the tripod, install the VCT-ST70I tripod adaptor
(not supplied) on the camera module.
Use a tripod screw with a protrusion (
from the installation surface, as follows, and tighten the
screw using a hand screwdriver.
: 4.5 to 5.5 mm (0.18 to 0.22 inches)
Note
When you install the tripod adaptor, use the screws
supplied with the tripod adaptor.

Connecting the camera cable

Connect a commercially available IEEE1394b camera
cable to the IEEE1394b connector and the 1394b
interface connector of your PC. When you connect the
cable, insert the cable connector into the IEEE1394b
connector until it snaps into place, holding it. Then,
tighten the fixing screws placed on both sides of the
cable connector.
1 IEEE1394b connector
2 Fixing screws
3 IEEE1394b camera cable (not supplied)
4 IEEE1394b connector cap
The IEEE1394b connector on the right has a cover cap
exclusively for this camera. If you use this connector,
remove the cap. The unused connector shall be covered
with the cap.
Note
Loose fixing screws may cause a poor connection or
damage to the camera or cable. Be sure to tighten the
fixing screws.
When power supply from the
IEEE1394b connector is
insufficient
Power can be supplied to the camera module via the DC-
700/700CE camera adaptor (optional) and a camera
cable such as CCXC-12P05N (optional) if power supply
) extending
from the IEEE1394b connector is insufficient.
1 12-pin I/O connector
2 Camera cable (e.g. CCXC-12P05N)
3 to AC power source
4 CAMERA connector
5 AC IN connector
6 Trigger generator
7