Electronic Preset Metered Control Valve

Meter Programming

NOTE: Each meter is programmed in quarts
and calibrated for motor oil at the factory.
Change Unit of Measure
1. Insert a blunt tool (5/32 "allen wrench) into the access
hole in the back of the meter.
• See Figure 4.
2. Press and hold the tool for 2 seconds.
• The screen begins to flash and then displays the
current scale factor and unit of measure.
• The current unit of measure flashes.
• See Figure 5.
3. Press the TOTAL button to cycle through the
available units of measure (Quarts, Gallons, Pints, or
Liters).
CAUTION
The accumulated and resettable totals are lost
when changing to or from liters.
Once the required unit of measure displays:
4. Press the RESET button.
• The chosen unit of measure illuminates steady.
• The first digit of the value for the scale factor
flashes.
NOTE: Should Liters be set, the decimal
point flashes.To change to a comma:
4.1 Press the TOTAL button.
• The comma flashes.
4.2 Press the RESET button.
•The comma illuminates steady.
•The first digit of the scale factor flashes.
If the scale factor* does not need to be changed:
5. Insert the tool into the access hole in the back of the
meter once again.
6. Press and hold the tool.
• The screen flashes three (3) times and then goes
blank.
7. Press the RESET button.
• The normal delivery screen appears.
* The scale factor is a value that the meter uses to
calculate the amount of fluid measured.
Alemite Corporation
Figure 4 Meter Programming Access Hole
Figure 5 Scale Factor and Units of Measure Screen
7