Service
The UNii keypad has no serviceable parts or adjustment points. In the event of established defects,
the entire keypad must be replaced (in consultation with the support desk).
Safety
For proper use of the Mifare DESFire reader in the UNii keypad (UNii KPR), it must be mounted on a
non-metallic surface. The keypad is only suitable for indoor use and must not be used outside the
specified temperature and humidity. Only original Mifare DESFire tags may be used in combination
with the UNii keypad

Specifications

Power supply:
Consumption without reader 40mA at 12V in active mode
Consumption with reader
Consumption with reader
Bus:
Casing:
Mifare DESFire reader:
Test institute:
Tests:
EU Declaration of conformity: Alphatronics BV hereby declares that the type of radio equipment
UNii keypad KPR is in conformity with Directive 2014/53 / EU.
The full text of the EU declaration of conformity is available at the following internet address:
Alphatronics | UNii Decalaration of Conformity
Identification: a label has been fixed to the back plate on the inside of the housing, on the basis of
which the device can be identified. The label includes the name of the manufacturer, the model, a
production date (2 digits for the month, followed by 2 digits for the year), the security Grade and
the environmental class.
Labels may not be removed!
If the installation does not comply with Grade 1, 2 or 3, the labels MUST be removed or
made clear in another way that the installation is non-compliant!
The serial number must not be removed
7,5 – 14,8 VDC
75mA at 12V in stand-by
135mA at 12V in active mode with card presented
RS485 bus
Synthetic; 131mm x 97mm x 21mm (H x W x D). Weight: 160 gr
13,56Mhz, 26,85db
The testing in accordance with the aforementioned standards was
carried out by Kiwa Telefication BV, the Netherlands.
EMC: EN301489 v2.2.1
Safety: EN IEC 62368-1:2014 + A11:2017
Security: EN50131-3:2009, according to Grade 3, environmental
class II.
Radio: EN 300330 v2.1.1
Operating temperature: 0° C to +40° C
Storage temperature: -20° C to +60° C
Humidity 85% relative humidity @ 30° C
5