Safety Precautions
Read all safety precautions and installation instructions carefully before installing or servicing this fixture. Failure to comply with these instructions could result in potentially fatal electric shock and/or
property damage.
It is recommended that a qualified electrician perform all wiring. This fixture must be wired in accordance with all national and local electrical codes.
Do not handle any energized fixture or attempt to energize any fixture with wet hands or while standing on a wet or damp surface or in water.
This fixture is designed for use in a 120-277VAC, 60Hz fused circuit only. This fixture is compatible with a 0-10V dimmer.
To reduce the risk of electrical shock, and to assure proper operation, this fixture must be adequately grounded. To accomplish proper grounding, there must be a separate ground wire (green)
contact between this fixture and the ground connection of your main power supply panel.
This fixture is intended to be used for general outdoor lighting in dry, damp, or wet locations. For wet locations, fixture must be mounted at least 48 inches above ground level.
Disclaimer
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and
found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules and Canadian ICES-005 (B) / NMB-005 (B). These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following
measures:
• Reorient or relocate the receiver antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult with the dealer or an experienced radio/TV technician for help.
Any modifications to this fixture may void the warranty and interfere with the safe operation of the luminaire.
Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired
operation of the device.
Assembly Instructions
Step 1 – Preparing for installation
A. Disconnect electrical power at fuse or circuit breaker box before installing or servicing any
part of this fixture.
B. Carefully remove the fixture from the carton, remove components from hardware
kit.
C. Install mounting bracket (1) to the junction box (not included) using two screws (2)
to secure it.
Wiring – All wiring must take place inside junction box (not included)
Caution: Make sure power is off at fuse or circuit breaker box. Check power wires
for damage or scrapes. If power supply wires are within three inches of the LED
driver, use wire suitable for at least 90°C (194°F). Note: Most dwellings built
before 1985 have supply wire rated to 60°C. Consult a qualified electrician to
ensure correct branch circuit conductor before installing.
Step 2 – Wiring fixture
A. Make all wire connections to appropriate wire. Secure with wire nuts (provided).
B. Connect the green wire from the fixture to the supply power source ground wire.
C. For none-dimming fixture. Connect the white wire from the fixture to the white
(N) wire from supply power source. Connect the black fixture wire to the black (L)
wire from supply power source. Gray and purple wires are not to be used and must
be individually capped to prevent shorting.
D. For (0-10V) dimming. Connect the gray wire from the fixture to the dimmer source gray wire.
Connect the purple wire from the fixture to the dimmer source purple wire. Connect the white wire
from the fixture to the white (N) wire from dimming source per dimmer wiring instructions. Connect
the black wire from the fixture to the black (L) wire from dimmer supply power source per dimmer
wiring instructions.
E. Do not mix wires. Pull on each wire lead to make sure connections are secure. Make certain no
bare wires are exposed outside of wire connectors. Tuck all connections neatly into the junction
box.
Step 3 – Mounting fixture
A. Place fixture (3) over the fixture mounting plate (1), aligning the holes on the bottom of fixture.
Then use two screws (4) to secure the fixture in place.
Step 4 – For wet application
A. Apply a small amount of silicone sealant (not provided) per manufacturer's instruction around
the perimeter of the fixture (3) where it contacts with the surface of the wall but not on the
bottom.
Step 5 – Restore power at fuse or circuit breaker box.
Limited Factory Warranty
AFX Inc. hereby warranty that this fixture is free from defects in materials and workmanship when installed and used under normal operating
conditions for a period of 5 years from date of shipment from factory. This warranty covers all component parts and extends only to replacement of
defective fixture or components; it does not cover failure due to improper installation, misuse, mishandling or damage incurred in transit.
Page 1 of 2
Model #: DKTW050410L30D2xx
Model #:
8061093 R1