Troubleshooting

Resetting Circuit Breaker:
1. Disconnect unit from the electrical supply.
2. Remove any object that may have stalled the brush roll.
3. Rotate the brush roll by hand to make sure it is not frozen in position.
4. Push reset button downward until it snaps into its original position.
5. Reconnect the Powerhead to the electrical supply of the electrified hose handle.
Problem
Motor is not working
Brush not run
Power nozzle not
picking up well.
Possible cause
1. Electrical connection at hose
coupling not made.
2. Power nozzle cord not firmly
plugged into the receptacle on
the hose handle.
3. Circuit breaker tripped.
1. Broken or worn belt.
2. The brush roller is blocked.
3. Bearing worn out.
1. Clogged air chamber.
2. Clogged wand or hose.
3. Brush is worn out.
Possible solution
Check the connection between the
electrified hose and the power unit.
Plug cord firmly in
Disconnect power, remove any object
that may have blocked the brush
roller, and reset the breaker.
Replace belt
Disconnect power, remove any object
that may have blocked the brush
roller.
Replace the brush and bearing
assmbly by distributor.
Disconnect power, remove the
obstruction.
Disconnect power, remove the
obstruction.
Replace the brush.
6