FLASHBACK (flames in the burner tube)
If a flashback occurs (indicated by a roaring noise),
immediately close off the cylinder valve.
Turn the heater OFF with the pull cord.
Disconnect the regulator and allow the heater to cool.
Check for blockages in the venturi ports. Clean with
compressed air, a small, soft brush or pipe cleaners.
If the problem persists in reuse, have the heater checked by a
qualified technician.

USING YOUR HEATER

1. Turn the gas supply on by opening the cylinder valve.
IGNITING THE UNIT
2. Pull and hold down the ignition cord on the right and maintain
tension for approximatley. 10 seconds to ignite the ceramic
burner. Keep tension on the ignition cord for a further 15 sec-
onds to heat the thermocouple, then release the ignition cord.
Ignition Cord
Ignition spark
Pull Down
3. Visually you should see a spark at the base of the centre
burner when holding down the ignition cord.
4. If the heater does not ignite the first time, wait for about 30
seconds and repeat step 2 above. This may require more than
one attempt.
TURNING THE HEATER OFF
5. Pull down the off cord on the left by giving it a quick tug and re-
lease. Once the heater is turned off the burners will no longer be
glowing orange giving indication that the unit is off.
6. Close the cylinder valve.
Shut Off Cord
Pull Down
11