Modes of Operation
ASG, Division of Jergens, Inc.
S. Waterloo Road | Cleveland, OH
15700
TAW Series Digital Torque Wrenches
Torque and Angle Model
User Manual
Peak Mode
In Peak mode, the maximum torque reading will remain on the OLED display when the
load is removed as long as the torque loaded is above the 10% of maximum capacity
threshold. The user has the option to store the reading in memory. If storage of the
reading is not required, the user may continue to the next measuring task.
Step 1: Press
to scroll to Peak Mode
Step 2: Press
to operate in Peak Mode
Step 3: Press
to store the peak value if required
Just Angle Mode
In Just Angle Mode, the maximum torque reading will remain on the OLED display
when the load is removed as long as the torque loaded is above the 10% of
maximum capacity threshold. The angle turned from 5% of the tool span until
maximum torque reading is also displayed. The user has the option to store the
reading in memory. If storage of the reading is not required, the user may continue
to the next measuring task.
Step 1: Press
to scroll to Just Angle Mode
Step 2: Press
to operate in Just Angle Mode
Step 3: Press
to store the peak torque and peak angle values if necessary. If storage
is not required, then apply a new load to test again