Ambirad Apollo QH 45-3 Gebrauchsanweisung - Seite 6
Blättern Sie online oder laden Sie pdf Gebrauchsanweisung für Heizgerät Ambirad Apollo QH 45-3 herunter. Ambirad Apollo QH 45-3 20 Seiten. Quartz glow instant infra-red heaters
1. When wall mounting, securely fasten the L-
shaped wall brackets to the mounting
surface using both of the fixing holes in the
short part of the bracket .
Refer
to
Table
positioning of the heater. Please note. Wall
fixings are not supplied. They should be
selected to substantially support the weight
of the installation. If in doubt contact a
professional for advice
2. When wall mounting, fix in the required
angular position by tightening the fixing bolts
on the brackets at the rear of the heater as
shown below.
The heater should face directly down when
hanging. Ensure that the serrated washer is
placed between the surface of the wall
bracket and the bracket on the heater.
• SOR 15 ONLY - When vertically mounting,
ensure the mounting surface is angled so
the heater projects downwards. Do not
position the heater at an angle more than
45° and less than 30° to the horizontal as
shown. Position the heater so the cord is
exiting the terminal box pointing down.
1
for
recommended
3. When hanging from a ceiling two equal
length and gauge chains are required and
should be selected with fixings that are more
than adequate to hold the weight of the
heater.
Ensure
minimum
distance from ceiling
is
adhered
to
shown below. If in
doubt
contact
professional
advice!
1.3.2.3 Two SOR 15/DL30/TW45 units
• Two Sorrento heaters can be joined together
and can be hung from a ceiling from chains
(not supplied). In addition, the SOR15 can
be wall mounted horizontally or vertically.
DO NOT WALL MOUNT THE SORDL30
OR SORTW45 UNITS!
• When wall mounting two SOR15 heaters
horizontally, do not position the heater at an
angle more than 45° and less than 10° as
shown below.
as
a
for