AMCI 7551 Manual de inicio rápido - Página 3

Navegue en línea o descargue pdf Manual de inicio rápido para Unidad de control AMCI 7551. AMCI 7551 11 páginas. Intelligent ldt interface module
También para AMCI 7551: Apéndice del manual (3 páginas)

AMCI 7551 Manual de inicio rápido
Installation (cont'd)

Cable Installation

Cables can be ordered directly from the LDT manufacturer. Optionally, MTS specifies BELDEN #8105 for
use as an extention cable.
The following figures are wiring diagrams for Balluff and Temposonics II transducers. Follow the LDT
manufacturers' guidelines for maximum cable length and installation.
GRAY
8
GREEN
7
PINK
6
YELLOW
5
SHIELDS
4
WHITE
3
BLUE
2
BROWN
1
Module Connector
AMCI Part #: MS-8
Phoenix #:
MSTB1.5/8-ST-5.08
Module Connector
AMCI Part #: MS-8
Phoenix #:
MSTB1.5/8-ST-5.08
ORANGE/WHT
8
WHITE/ORN
7
GRAY/WHT
6
WHITE/GRY
5
SHIELDS
4
GREEN/WHT
3
WHITE/BLU
2
WHITE/GRN
1
+15V
GND
±15Vdc Power Supply
Plymouth Industrial Park, Terryville CT 06786
Tel: (203) 585-1254 Fax: (203) 584-1973
S
7500 I
ERIES
Overall Shield
+ STOP
- STOP
- INTERROGATE
+ INTERROGATE
SHIELDS
- 15 Vdc
+ 15 Vdc
SUPPLY GROUND
+15V
GND
-15V
±15Vdc Power Supply
AMCI and Balluff LDT Cable Drawing
Overall Shield
*
+ START/STOP
- START/STOP
- INTERROGATION
+ INTERROGATION
SHIELDS
- 15 Vdc
+ 15 Vdc
DC GROUND
BLUE/WHT
FRAME GND
BROWN/WHT
WHITE/BRN
-15V
Temposonics II LDT Cable Drawing
LDT I
NTELLIGENT
BELDEN CABLE #8105 or exact equ.
* Cable for Transducers with RPM Personality Module is shown.
For Transducers with DPM Personality Module, the following pins are renamed:
+ Start/Stop renamed to + Gate Out
- Start/Stop renamed to - Gate Out.
M
NTERFACE
ODULE
3