Aperio Integration
Aperio® Hardware Setup
Connecting the AH40 Hub to the Local Area Network (LAN)
The AH40 communicates to the Mercury enabled Controller via a Networked Ethernet Connection. At a
Minimum, the use of a CAT-5e connector complying with 10BASE-T / 100BASE-TX standard must be used.
The connection can be achieved by connecting the Ethernet cable to the J700 connector located on the
back of the device as pictured below.
The device can be powered through the use of the J800 port connector to an extrernal power source or by
using a POE+ Enabled Switch. The Connection must be an IEEE 802.3.af compliant Power Sourcing Device.
Recommended power source is 1.2w and less than 3 amps. If the possibility of surges over 3 amps exists
then a over current protection device must be used.